Calpeda
Items 1 - 2 of 2
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer three-phase induction motor
- Rated voltage: 230 V / 400 V ±10 %, 50 Hz
- Engine rated power P2: 0,55 kW / 0,75 HP
- Rated current: 3 A at 230 V / 1,7 A at 400 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 2,4 m3/h
- Maximum pump head according to the characteristic curve: 47 m
- Characteristic curve Q/H: 0 m3/h → 47 m; 0,48 m3/h → 42 m; 0,6 m3/h → 41 m; 0,75 m3/h → 40 m; 1 m3/h → 37 m; 1,2 m3/h → 34 m; 1,5 m3/h → 30 m; 1,89 m3/h → 25 m; 2,4 m3/h → 17 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1; Pressure side DN2 G 1
- Dimensions: a 84 mm; A 112 mm; a1 28 mm; AA 22 mm; AB 134 mm; B 90 mm; BB 106 mm; fM 318 mm; H 71 mm; h1 142 mm; h2 41 mm; HA 10 mm; HD 182 mm; K 7 mm; l5 21 mm; w 128 mm
- Article weight: 10 kg
- Materials: pump housing and lantern GJL 200; Brass impeller CW617N; shaft AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Revision: A
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer three-phase induction motor
- Rated voltage: 230 V / 400 V ±10 %, 50 Hz
- Engine rated power P2: 0,55 kW / 0,75 HP
- Rated current: 3 A at 230 V / 1,7 A at 400 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 2,4 m3/h
- Maximum pump head according to the characteristic curve: 47 m
- Characteristic curve Q/H: 0 m3/h → 47 m; 0,48 m3/h → 42 m; 0,6 m3/h → 41 m; 0,75 m3/h → 40 m; 1 m3/h → 37 m; 1,2 m3/h → 34 m; 1,5 m3/h → 30 m; 1,89 m3/h → 25 m; 2,4 m3/h → 17 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1; Pressure side DN2 G 1
- Dimensions: a 84 mm; A 112 mm; a1 28 mm; AA 22 mm; AB 134 mm; B 90 mm; BB 106 mm; fM 318 mm; H 71 mm; h1 142 mm; h2 41 mm; HA 10 mm; HD 182 mm; K 7 mm; l5 21 mm; w 128 mm
- Article weight: 10,9 kg
- Materials: Pump housing and lantern bronze CC480K; Brass impeller CW617N; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Revision: A
Items 1 - 2 of 2