Calpeda
Items 1 - 18 of 18
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Maximum power consumption P1: 0,29 kW
- Rated current: 1,6 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 5,9 kg
- Materials: pump housing and lantern GJL 200; Brass impeller CW617N; shaft AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Maximum power consumption P1: 0,29 kW
- Rated current: 1,6 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 6,3 kg
- Materials: Pump housing and lantern bronze CC480K; Brass impeller CW617N; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: Horizontal, multi-stage, self-priming centrifugal pump of block construction; One-piece shell of stainless steel with chromium-nickel and steps of noryl
- Design: Stainless steel design with jacket housing of AISI 304
- Applications: For water supply, home and garden applications and watering
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,37 kW / 0,5 HP
- Maximum power consumption P1: 0,57 kW
- Rated current: 3 A for 230 V
- Rated speed: 2800 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: up to 4 m3/h
- Maximum pump head according to the characteristic curve: 32 m
- Characteristic curve Q/H: 0 m3/h → 32 m; 1 m3/h → 28 m; 2 m3/h → 24 m; 3 m3/h → 19 m; 4 m3/h → 14 m
- Media temperature: 0 to +35 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 8 m
- Maximum permissible working pressure: 8 bar
- Connections according to ISO 228: suction side DN1 G 1; Pressure side DN2 G 1
- Dimensions: a 115 mm; b 30 mm; fM 362 mm; g1 10 mm; h1 116 mm; h2 61 mm; HD 176 mm; l5 161 mm; m1 33 mm; m3 8 mm; n1 146 mm; n2 112 mm; s 9 mm; w 102 mm; w1 102 mm
- Article weight: 6,8 kg
- Materials: pump housing and housing cover AISI 304; shaft AISI 430F; suction and stepped housings and impeller Noryl PPO-GF20; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,45 kW / 0,6 HP
- Maximum power consumption P1: 0,67 kW
- Rated current: 3,5 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 1,89 m3/h
- Maximum pump head according to the characteristic curve: 38 m
- Characteristic curve Q/H: 0 m3/h → 38 m; 0,38 m3/h → 36 m; 0,48 m3/h → 35 m; 0,6 m3/h → 33,5 m; 0,75 m3/h → 31,5 m; 1 m3/h → 29 m; 1,2 m3/h → 26 m; 1,5 m3/h → 22 m; 1,89 m3/h → 15 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 3/4; Printing side DN2 G 3/4
- Dimensions: a 72 mm; A 100 mm; a1 23 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 272 mm; H 63 mm; h1 126 mm; h2 27 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 17 mm; w 109 mm
- Article weight: 7,6 kg
- Materials: pump housing and lantern GJL 200; Brass impeller CW617N; shaft AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,45 kW / 0,6 HP
- Maximum power consumption P1: 0,67 kW
- Rated current: 3,6 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 1,89 m3/h
- Maximum pump head according to the characteristic curve: 38 m
- Characteristic curve Q/H: 0 m3/h → 38 m; 0,38 m3/h → 36 m; 0,48 m3/h → 35 m; 0,6 m3/h → 33,5 m; 0,75 m3/h → 31,5 m; 1 m3/h → 29 m; 1,2 m3/h → 26 m; 1,5 m3/h → 22 m; 1,89 m3/h → 15 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 3/4; Printing side DN2 G 3/4
- Dimensions: a 72 mm; A 112 mm; a1 23 mm; AA 22 mm; AB 134 mm; B 90 mm; BB 106 mm; fM 307 mm; H 71 mm; h1 134 mm; h2 27 mm; HA 10 mm; HD 182 mm; K 7 mm; l5 17 mm; w 122 mm
- Article weight: 9,7 kg
- Materials: Pump housing and lantern bronze CC480K; Brass impeller CW617N; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Revision: A
- Construction: High quality self-priming, ingot type, ingot type, with built-in ejector and pump housing of stainless steel
- Design: Stainless steel design with pump housing and housing cover from AISI 304
- Applications: For well extraction, extraction of water with air or gas content, pressure increase, domestic water supply, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2800 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: up to 6 m3/h
- Maximum pump head according to the characteristic curve: 58 m
- Characteristic curve Q/H: 0 m3/h → 58 m; 0,5 m3/h → 54,7 m; 1 m3/h → 51,5 m; 2 m3/h → 46 m; 2,4 m3/h → 44 m; 3 m3/h → 41,3 m; 3,2 m3/h → 40,4 m; 3,6 m3/h → 38,7 m; 4 m3/h → 37 m; 4,5 m3/h → 34,7 m; 5 m3/h → 32,5 m; 5,5 m3/h → 30,5 m; 6 m3/h → 28,5 m
- Media temperature: 0 to +35 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 8 bar
- Connections according to ISO 228: suction side DN1 G 1 1/4; Pressure side DN2 G 1
- Dimensions: a 140 mm; b 33 mm; fM 488.5 mm; g1 11 mm; h1 152 mm; h2 68 mm; HD 240 mm; l5 213.5 mm; m1 37.5 mm; m2 28 mm; m3 9.5 mm; n1 185 mm; n2 155 mm; s 9.5 mm; w 113 mm; w1 157.5 mm
- Article weight: 17,4 kg
- Materials: pump housing and housing cover AISI 304; wheel brass CW617N, at NGX 2/80, 3/100 and 4/110 Noryl PPO-GF20; Diffuser and ejector Noryl PPO-GF20; shaft AISI 430F/AISI 303; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Brass runner
- Construction: High quality self-priming, ingot type, ingot type, with built-in ejector and pump housing of stainless steel
- Design: Stainless steel design with pump housing and housing cover from AISI 304
- Applications: For well extraction, extraction of water with air or gas content, pressure increase, domestic water supply, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2800 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 8,4 m3/h
- Maximum pump head according to the characteristic curve: 46,5 m
- Characteristic curve Q/H: 0 m3/h → 46,5 m; 0,5 m3/h → 45 m; 1 m3/h → 43,5 m; 2 m3/h → 40,5 m; 2,4 m3/h → 39,3 m; 3 m3/h → 37,5 m; 3,2 m3/h → 37 m; 3,6 m3/h → 36 m; 4 m3/h → 35 m; 4,5 m3/h → 33,5 m; 5 m3/h → 32,5 m; 5,5 m3/h → 31,2 m; 6 m3/h → 30 m; 6,5 m3/h → 28,5 m; 7 m3/h → 27,5 m; 8 m3/h → 25,5 m; 8,4 m3/h → 24,5 m3/h
- Media temperature: 0 to +35 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 8 bar
- Connections according to ISO 228: suction side DN1 G 1 1/4; Pressure side DN2 G 1
- Dimensions: a 140 mm; b 33 mm; fM 488.5 mm; g1 11 mm; h1 152 mm; h2 68 mm; HD 240 mm; l5 213.5 mm; m1 37.5 mm; m2 28 mm; m3 9.5 mm; n1 185 mm; n2 155 mm; s 9.5 mm; w 113 mm; w1 157.5 mm
- Article weight: 17,4 kg
- Materials: pump housing and housing cover AISI 304; wheel brass CW617N, at NGX 2/80, 3/100 and 4/110 Noryl PPO-GF20; Diffuser and ejector Noryl PPO-GF20; shaft AISI 430F/AISI 303; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Brass runner
- Construction: Self-priming flat well jet pump in block construction with built-in ejector
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For well extraction, pressure increase, clean liquids or slightly contaminated surface water, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: up to 6 m3/h
- Maximum pump head according to the characteristic curve: 61,8 m
- Characteristic curve Q/H: 0 m3/h → 61,8 m; 0,5 m3/h → 59 m; 1 m3/h → 57 m; 1,5 m3/h → 54 m; 2 m3/h → 51 m; 2,5 m3/h → 48 m; 3 m3/h → 45 m; 3,5 m3/h → 43 m; 4 m3/h → 40 m; 4,5 m3/h → 37,5 m; 5 m3/h → 35 m; 5,5 m3/h → 33 m; 6 m3/h → 30 m
- Media temperature: to +40 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 10 bar
- Connections according to ISO 228: suction side DN1 G 1 1/2; Pressure side DN2 G 1
- Dimensions: a 160 mm; a1 10 mm; b 40 mm; fM 560 mm; g1 11 mm; h1 165 mm; h2 57 mm; HD 240 mm; m1 60 mm; m3 10 mm; n1 215 mm; n2 175 mm; s 11.5 mm; w 115 mm
- Article weight: 29,6 kg
- Materials: pump housing, cover and diffuser plate GJL 200; Brass impeller CW617N; Diffuser and nozzle Noryl PPO-GF20; shaft AISI 430F/AISI 303; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal
- Construction: Self-priming flat well jet pump in block construction with built-in ejector
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For well extraction, pressure increase, clean liquids or slightly contaminated surface water, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 9,5 m3/h
- Maximum pump head according to the characteristic curve: 48,5 m
- Characteristic curve Q/H: 0 m3/h → 48,5 m; 0,5 m3/h → 47 m; 1 m3/h → 45 m; 1,5 m3/h → 43,5 m; 2 m3/h → 42 m; 2,5 m3/h → 41 m; 3 m3/h → 40 m; 3,5 m3/h → 38 m; 4 m3/h → 37 m; 4,5 m3/h → 36 m; 5 m3/h → 35 m; 5,5 m3/h → 33 m; 6 m3/h → 32 m; 6,5 m3/h → 31 m; 7 m3/h → 30 m; 8 m3/h → 27 m; 9 m3/h → 24 m; 9,5 m3/h → 23 m3/h
- Media temperature: to +40 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 10 bar
- Connections according to ISO 228: suction side DN1 G 1 1/2; Pressure side DN2 G 1
- Dimensions: a 160 mm; a1 10 mm; b 40 mm; fM 560 mm; g1 11 mm; h1 165 mm; h2 57 mm; HD 240 mm; m1 60 mm; m3 10 mm; n1 215 mm; n2 175 mm; s 11.5 mm; w 115 mm
- Article weight: 29,6 kg
- Materials: pump housing, cover and diffuser plate GJL 200; Brass impeller CW617N; Diffuser and nozzle Noryl PPO-GF20; shaft AISI 430F/AISI 303; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- cast iron design; Pump housing and lantern made of GJL 200 with cataphoresis coating
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,55 kW / 0,75 HP
- Maximum power consumption P1: 0,78 kW
- Rated current: 4,5 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S1 (continuous duty)
- Flow according to characteristic curve: to 15 m3/h
- Maximum pump head according to the characteristic curve: 13 m
- Characteristic curve Q/H: 0 m3/h → 13 m; 6,6 m3/h → 12 m; 9,6 m3/h → 11 m; 10,8 m3/h → 10 m; 12 m3/h → 9,5 m; 13,2 m3/h → 9 m; 15 m3/h → 8 m
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2; Printing page DN2 G2
- Dimensions: a 195 mm; b 50 mm; fM 510 mm; g1 12 mm; h1 230 mm; h2 50 mm; h5 330 mm; HD 228 mm; l1 106 mm; l2 99 mm; m1 100 mm; m2 70 mm; n1 190 mm; n2 140 mm; n3 30 mm; s 14 mm; w 220 mm
- Weight: 29,7 kg
- Materials: impeller GJL 200 (plated brass P-Cu Zn 40 Pb 2 in the case of NMP 32/12); shaft AISI 303; sieve cover GJL 200; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
- Construction: Self-priming centrifugal pump of block construction with open impeller and integrated backflow preventer for automatic re-priming
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean or easily polluted water; solids up to 10 mm at A 40/A 50 and up to 15 mm at A 65/A 80; For drainage, irrigation and municipal and industrial applications
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2,1 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 33 m3/h
- Maximum pump head according to the characteristic curve: 20,5 m
- Characteristic curve Q/H: 0 m3/h → 20,5 m; 6 m3/h → 19,5 m; 9 m3/h → 19 m; 12 m3/h → 18 m; 15 m3/h → 17 m; 18 m3/h → 15,5 m; 21 m3/h → 14 m; 24 m3/h → 12,5 m; 27 m3/h → 10,5 m; 30 m3/h → 8 m; 33 m3/h → 5 m
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 6 bar; A 80-170 to 10 bar
- Connections according to ISO 228: suction side DN1 G 2; Pressure side DN2 G 2
- Dimensions: a 147 mm; b 50 mm; fM 490 mm; g1 12 mm; h1 231 mm; h2 64 mm; HD 223 mm; l1 96 mm; l2 102 mm; m1 100 mm; m2 70 mm; n1 190 mm; n2 140 mm; n3 30 mm; s 16 mm; w 263 mm
- Article weight: 29,9 kg
- Materials: pump housing, suction housing and impeller GJL 200; shaft depending on the size AISI 303 or AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- bronze version; Pump housing and lantern of bronze CC480K
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,55 kW / 0,75 HP
- Maximum power consumption P1: 0,78 kW
- Rated current: 4,5 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S1 (continuous duty)
- Flow according to characteristic curve: to 15 m3/h
- Maximum pump head according to the characteristic curve: 13 m
- Characteristic curve Q/H: 0 m3/h → 13 m; 6,6 m3/h → 12 m; 9,6 m3/h → 11 m; 10,8 m3/h → 10 m; 12 m3/h → 9,5 m; 13,2 m3/h → 9 m; 15 m3/h → 8 m
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2; Printing page DN2 G2
- Dimensions: a 195 mm; b 50 mm; fM 510 mm; g1 12 mm; h1 230 mm; h2 50 mm; h5 330 mm; HD 228 mm; l1 106 mm; l2 99 mm; m1 100 mm; m2 70 mm; n1 190 mm; n2 140 mm; n3 30 mm; s 14 mm; w 220 mm
- Weight: 33,7 kg
- Materials: bronze impeller CC480K (plated brass P-Cu Zn 40 Pb 2 in the case of BNMP 32/12); shaft AISI 316; bronze CC480K sieve cover; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- cast iron design; Pump housing and lantern made of GJL 200 with cataphoresis coating
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 24 m3/h
- Maximum pump head according to the characteristic curve: 23 m
- Characteristic curve Q/H: 0 m3/h → 23 m; 6,6 m3/h → 22,5 m; 9,6 m3/h → 21,5 m; 10,8 m3/h → 21 m; 12 m3/h → 20,5 m; 13,2 m3/h → 20 m; 15 m3/h → 19 m; 18,9 m3/h → 16 m; 21 m3/h → 15 m; 24 m3/h → 12 m3/h
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2; Printing page DN2 G2
- Dimensions: a 195 mm; b 50 mm; fM 510 mm; g1 12 mm; h1 230 mm; h2 50 mm; h5 330 mm; HD 228 mm; l1 106 mm; l2 99 mm; m1 100 mm; m2 70 mm; n1 190 mm; n2 140 mm; n3 30 mm; s 14 mm; w 220 mm
- Weight: 33,8 kg
- Materials: impeller GJL 200 (plated brass P-Cu Zn 40 Pb 2 in the case of NMP 32/12); shaft AISI 303; sieve cover GJL 200; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
- Construction: Self-priming flat well jet pump in block construction with built-in ejector
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For well extraction, pressure increase, clean liquids or slightly contaminated surface water, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: up to 6 m3/h
- Maximum pump head according to the characteristic curve: 61,8 m
- Characteristic curve Q/H: 0 m3/h → 61,8 m; 0,5 m3/h → 59 m; 1 m3/h → 57 m; 1,5 m3/h → 54 m; 2 m3/h → 51 m; 2,5 m3/h → 48 m; 3 m3/h → 45 m; 3,5 m3/h → 43 m; 4 m3/h → 40 m; 4,5 m3/h → 37,5 m; 5 m3/h → 35 m; 5,5 m3/h → 33 m; 6 m3/h → 30 m
- Media temperature: to +40 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 10 bar
- Connections according to ISO 228: suction side DN1 G 1 1/2; Pressure side DN2 G 1
- Dimensions: a 160 mm; a1 10 mm; b 40 mm; fM 560 mm; g1 11 mm; h1 165 mm; h2 57 mm; HD 240 mm; m1 60 mm; m3 10 mm; n1 215 mm; n2 175 mm; s 11.5 mm; w 115 mm
- Article weight: 34 kg
- Materials: Pump housing, cover and diffuser plate bronze CC480K; Brass impeller CW617N; Diffuser and nozzle Noryl PPO-GF20; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal
- Construction: Self-priming flat well jet pump in block construction with built-in ejector
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For well extraction, pressure increase, clean liquids or slightly contaminated surface water, garden watering and water jet cleaning
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IP54
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 9,5 m3/h
- Maximum pump head according to the characteristic curve: 48,5 m
- Characteristic curve Q/H: 0 m3/h → 48,5 m; 0,5 m3/h → 47 m; 1 m3/h → 45 m; 1,5 m3/h → 43,5 m; 2 m3/h → 42 m; 2,5 m3/h → 41 m; 3 m3/h → 40 m; 3,5 m3/h → 38 m; 4 m3/h → 37 m; 4,5 m3/h → 36 m; 5 m3/h → 35 m; 5,5 m3/h → 33 m; 6 m3/h → 32 m; 6,5 m3/h → 31 m; 7 m3/h → 30 m; 8 m3/h → 27 m; 9 m3/h → 24 m; 9,5 m3/h → 23 m3/h
- Media temperature: to +40 °C
- Maximum ambient temperature: to 40 °C
- Maximum permissible working pressure: 10 bar
- Connections according to ISO 228: suction side DN1 G 1 1/2; Pressure side DN2 G 1
- Dimensions: a 160 mm; a1 10 mm; b 40 mm; fM 560 mm; g1 11 mm; h1 165 mm; h2 57 mm; HD 240 mm; m1 60 mm; m3 10 mm; n1 215 mm; n2 175 mm; s 11.5 mm; w 115 mm
- Article weight: 34 kg
- Materials: Pump housing, cover and diffuser plate bronze CC480K; Brass impeller CW617N; Diffuser and nozzle Noryl PPO-GF20; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- bronze version; Pump housing and lantern of bronze CC480K
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 24 m3/h
- Maximum pump head according to the characteristic curve: 23 m
- Characteristic curve Q/H: 0 m3/h → 23 m; 6,6 m3/h → 22,5 m; 9,6 m3/h → 21,5 m; 10,8 m3/h → 21 m; 12 m3/h → 20,5 m; 13,2 m3/h → 20 m; 15 m3/h → 19 m; 18,9 m3/h → 16 m; 21 m3/h → 15 m; 24 m3/h → 12 m3/h
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2; Printing page DN2 G2
- Dimensions: a 195 mm; b 50 mm; fM 510 mm; g1 12 mm; h1 230 mm; h2 50 mm; h5 330 mm; HD 228 mm; l1 106 mm; l2 99 mm; m1 100 mm; m2 70 mm; n1 190 mm; n2 140 mm; n3 30 mm; s 14 mm; w 220 mm
- Weight: 37 kg
- Materials: bronze impeller CC480K (plated brass P-Cu Zn 40 Pb 2 in the case of BNMP 32/12); shaft AISI 316; bronze CC480K sieve cover; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- cast iron design; Pump housing and lantern made of GJL 200 with cataphoresis coating
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 60 m3/h
- Maximum pump head according to the characteristic curve: 12,9 m
- Characteristic curve Q/H: 0 m3/h → 12,9 m; 18,9 m3/h → 12 m; 21 m3/h → 12 m; 24 m3/h → 11,5 m; 30 m3/h → 10,5 m; 42 m3/h → 8 m; 48 m3/h → 7 m; 54 m3/h → 5 m; 60 m3/h → 3,5 m3/h
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2 1/2; Printing page DN2 G2 1/2
- Dimensions: a 205 mm; b 50 mm; fM 540 mm; g1 12 mm; h1 262 mm; h2 60 mm; h5 370 mm; HD 240 mm; l1 120 mm; l2 117 mm; m1 100 mm; m2 70 mm; n1 240 mm; n2 190 mm; n3 37 mm; s 14 mm; w 234 mm
- Weight: 37,7 kg
- Materials: impeller GJL 200 (plated brass P-Cu Zn 40 Pb 2 in the case of NMP 32/12); shaft AISI 303; sieve cover GJL 200; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
- Monoblock self-priming centrifugal pump with integrated pre-filter; Sieve basket with Ø 3 mm perforations
- bronze version; Pump housing and lantern of bronze CC480K
- water circulation in swimming pool filtration systems; For clean or slightly polluted water containing suspended solids
- 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 1,5 kW / 2 HP
- Maximum power consumption P1: 2 kW
- Rated current: 9,2 A at 230 V
- Rated speed: 2900 min-1
- Degree of protection: IPX4
- Insulation class: F
- Operation mode: S3 60 %
- Flow according to characteristic curve: to 60 m3/h
- Maximum pump head according to the characteristic curve: 12,9 m
- Characteristic curve Q/H: 0 m3/h → 12,9 m; 18,9 m3/h → 12 m; 21 m3/h → 12 m; 24 m3/h → 11,5 m; 30 m3/h → 10,5 m; 42 m3/h → 8 m; 48 m3/h → 7 m; 54 m3/h → 5 m; 60 m3/h → 3,5 m3/h
- Maximum water temperature: 60 °C
- Maximum ambient temperature: 40 °C
- Total suction height: to 7 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G2 1/2; Printing page DN2 G2 1/2
- Dimensions: a 205 mm; b 50 mm; fM 540 mm; g1 12 mm; h1 262 mm; h2 60 mm; h5 370 mm; HD 240 mm; l1 120 mm; l2 117 mm; m1 100 mm; m2 70 mm; n1 240 mm; n2 190 mm; n3 37 mm; s 14 mm; w 234 mm
- Weight: 41,9 kg
- Materials: bronze impeller CC480K (plated brass P-Cu Zn 40 Pb 2 in the case of BNMP 32/12); shaft AISI 316; bronze CC480K sieve cover; filter AISI 304; Slip ring seal carbon/ceramic/FPM
- Design according to: EN 60034-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; Degree of protection IP55; Special sliding ring seal; Higher liquid or ambient temperatures
Items 1 - 18 of 18