AUCOM
|
Mains voltage |
V4 = 3x 200 to 440 VAC (+ 10 % / - 15 %); V6 = 3x 200 to 575 VAC (+ 10 % / - 15 %) |
||
|
Drive voltage |
C1: 110 to 240 VAC (+10 % / -15 %) or: 380 to 440 VAC (+10 % / -15 %) |
||
|
C2: 24 VAC/VDC (± 20%) |
|||
|
Network frequency |
45 Hz – 60 Hz |
||
|
Designation of the structure |
Semiconductor motor starter with internal bypass - Form 1, |
||
|
Inputs |
Start [01 terminal]: Normally open |
||
|
Stop [02 terminal]: Normally closed |
|||
|
Outputs |
Relay main contactor [13,14 terminal]: Normally open |
||
|
Programmable relay [terminal 23, 24]: Normally open |
|||
|
Protection type |
Sizes 1 & 2 IP20, Size 3 IP00 |
||
|
Operating temperature |
-10 °C to +60 °C |
||
|
Storage temperature |
-25 °C to +60 °C (up to +70 °C for max. 24 hours) |
||
|
Moisture |
5 % to 95 % relative humidity |
||
|
Degree of pollution |
Degree of pollution 3 |
||
|
Vibration test |
according to IEC 60068 - Fc sinusoidal |
||
|
4 Hz to 13,2 Hz: ± 1 mm amplitude; 13,2 Hz to 200 Hz: ± 0,7 g |
|||
|
EMV emission |
Radio interference suppression (EMV) Class B |
||
|
EMV security |
IEC 61000-2-4 (Class 3), EN / IEC 61800-3 |
||
|
Heat release |
During take-off: 3,0 Watts / Amperes |
||
|
During operation: 10 Watt (typical) |
|||
|
Accessories (optional) |
Remote control, PC software |
||
|
Communication options |
DeviceNet, Modbus, Profibus, Profinet, Ethernet/IP, Modbus TC/IP, |
||
|
Certificates |
CCC: GB 14048.6; CE: EN 60947-4-2; UL / C-UL: UL 508; EAC: TP TC 004/2011, TP TC 020/2011; Marine: Lloyds Marine No 1 Specification; RCM: IEC 60947-4-2 |
||