3AC pole-changing motors
Standard three-phase motors
1,40/2,00 kW; S1; 1405/2750 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 9,52/6,94 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,4 x In; starting torque 1,8/1,8 x Mn; tilting moment 2,2/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
2,00/2,60 kW; S1; 1395/2810 1/min; 400V ∆/YY 50 Hz 3AC; 4,2/5,3 A; 13,7/8,8 Nm
Power values correspond to basic version D / YY, 6 clamps (constant torque)
attracting current 4,8/4,7 x In; starting torque 1,6/1,8 x Mn; tilting moment 2,1/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,006 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
17/27 kW; S1; 740/1470 min-1; 400V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 219/175 Nm
attract current 6,0/6,9xIn; starting torque 2,7/1,8xMn; tilting moment 2,7/2,4xMn
Efficiency 85,2/87,6%
Power values Basic design (constant torque)
7,0/28 kW; S1; 735/1470 min-1; 400V Y/YY 50 Hz 3AC 14,8/54,0 A; 91/182 Nm
attract current 5,2/6,3xIn; starting torque 1,8/2,1xMn; tilting moment 2,3/2,6xMn
Efficiency 84,5/89,7%
Power values Fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU312.C3; Camp BS: 6312.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010