3AC pole-changing motors
Standard three-phase motors
1,40/2,00 kW; S1; 1405/2750 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 9,52/6,94 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,4 x In; starting torque 1,8/1,8 x Mn; tilting moment 2,2/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
1,60/2,40 kW; S1; 1405/2750 1/min;
400V ∆/YY 50 Hz 3AC; 3,7/4,8 A; 10,9/8,24 Nm
Power values correspond to basic design (constant torque)
attracting current 5,0/4,8 x In; starting torque 1,9/1,4 x Mn; tilting moment 2,1/2,0 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0148 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,10 kW; S1; 935/1410 1/min; 400V ∆/YY 50 Hz 3AC; 2,2/2,9 A; 7,15/7,45 Nm
Power values correspond to basic design (constant torque)
attracting current 2,2/2,9 x In; starting torque 1,6/1,4 x Mn; tilting moment 3,6/4,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0032 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency 63,7%/67,7%
0,55/1,00 kW; S1; 695/1380 1/min; 400V ∆/YY 50 Hz 3AC; 2,1/2,2 A; 7,56/6,92 Nm
attracting current 3,0/3,9 x In; starting torque 1,8/1,4 x Mn; Tilting moment 2,0/2,0 x Mn
Efficiency at nominal load 62%/75%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
1,10/1,40 kW; S1; 1410/2785 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 7,45/4,80 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,5 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,1/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0023 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,37/0,75 kW; S1; 705/1385 1/min; 400V ∆/YY 50 Hz 3AC; 1,7/1,7 A; 5,01/5,17 Nm
attracting current 3,0/4,2 x In; starting torque 2,1/1,5 x Mn; Tilting moment 2,3/1,8 x Mn
Efficiency at nominal load 55%/73%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
7,20/12,0 kW; S1; 720/1440 1/min; 400V ∆/YY 50 Hz 3AC; 19,4/22,0 A; 95,5/79,6 Nm
Power values correspond to basic design (constant torque)
attracting current 5,6/7,2 x In; starting torque 2,1/1,9 x Mn; tilting moment 2,9/2,7 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø42 x 110 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6309.ZZ.C3; Camp BS: 6309.ZZ.C3; moment of inertia 0,096 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 80,2%/87,2% Efficiency at 3/4 load 83,5%/88,0% Efficiency at rated load 83,9%/87,3% Sound pressure level 63/67 dB
4,70/8,40 kW; S1; 725/1435 1/min; 400V ∆/YY 50 Hz 3AC; 13,0/15,5 A; 61,9/55,9 Nm
Power values correspond to basic design (constant torque)
attracting current 5,4/6,2 x In; starting torque 2,0/1,7 x Mn; tilting moment 2,9/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø42 x 110 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6309.ZZ.C3; Camp BS: 6309.ZZ.C3; moment of inertia 0,07 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 77,8%/86,7% Efficiency at 3/4 load 81,7%/87,2% Efficiency at rated load 82,7%/86,1% Sound pressure level 71/67 dB