3AC pole-changing motors
Standard three-phase motors
0,75/0,95 kW; S1; 1360/2780 min-1; 400V Y/YY 50 Hz 3AC 2,1/2,5 A; 5,23/3,26 Nm
attracting current 3,1/3,8 x In; starting torque 1,7/1,9 x Mn; Tilting moment 1,8/2,0 x Mn
Efficiency at nominal load 65%/60%
Power values fan design (square torque)
0,25/1,00 kW; S1; 1370/2780 1/min; 400VY/YY 50 Hz 3AC; 0,75/2,32 A; 1,75/3,44 Nm
attracting current 3,0/3,8 x In; starting torque 1,6/1,9 x Mn; tilting moment 1,7/2,0 Mn
Power values correspond to fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); Housing material up to frame size 132 aluminium, from frame size 160 grey cast iron; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001874 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
- 2,50/3,30 kW
- S1
- 1380/2785 1/min
- 400V ∆/YY 50 Hz 3AC
- 4,2/5,3 A
- 17,3/11,3 Nm
- Power values correspond to basic design (constant torque)
- attracting current 4,8/4,9 x In
- starting torque 1,7/1,8 x Mn
- tilting moment 2,0/2,2 x Mn
- IEC 60034-1 design
- sound limit value according to IEC 60034-9
- shaft Ø28 x 60 mm
- heat class 155(F)
- in the case of B3 design, feet screwed to frame size132
- Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron
- Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3
- Camp BS: 6206.ZZ.C3
- moment of inertia 0,0065 kgm2
- half-wedge weighting species
- vibration stage "A"
- terminal box layer at the top
- clamp/strand number 6
- the possibility of rotation of the terminal box yes
- Paint RAL5010
0,30/0,55 kW; S1; 660/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,5/1,4 A; 4,34/3,89 Nm
attracting current 2,0/2,7 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,5/1,5 x Mn
Efficiency at nominal load 48%/64%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,00207 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
2,00/2,60 kW; S1; 1395/2810 1/min; 400V ∆/YY 50 Hz 3AC; 4,2/5,3 A; 13,7/8,8 Nm
Power values correspond to basic version D / YY, 6 clamps (constant torque)
attracting current 4,8/4,7 x In; starting torque 1,6/1,8 x Mn; tilting moment 2,1/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,006 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,25 kW; S1; 715/1425 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/2,7 A; 9,35/8,38 Nm
attracting current 3,6/5,1 x In; starting torque 2,2/1,7 x Mn; Tilting moment 2,8/2,5 x Mn
Efficiency at nominal load 64%/78%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,90/1,70 kW; S1; 715/1415 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 12,0/11,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 2,2/1,3 x Mn; tilting moment 3,1/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0094 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,22/0,40 kW; S1; 670/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,3/1,1 A; 3,13/2,83 Nm
attracting current 2,0/2,8 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,6/1,5 x Mn
Efficiency at nominal load 46%/60%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001693 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
attracting current 3,7/4,1 x In; starting torque 2,0/1,5 x Mn; Tilting moment 2,2/2,4 x Mn
Efficiency at nominal load [%] 63,7/66,5
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001578 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Switchable for constant or square torque.
45,0/65,0 kW; S1; 990/1480 min-1; 400V Δ/YY 50 Hz 3AC; 80,0/110 A; 434/419 Nm
attracting current 8,5/6,7 x In; starting torque 2,8/1,4xMn; tilting moment 2,6/1,9xMn
Efficiency 90,6/91,8%
Power values Basic (constant torque)
22,0/65,0 kW; S1; 983/1480 1/min; 380-420VY/Y 50 Hz 3AC; 39&108A; 214/419 Nm
attracting current 5,5/6,6 x In; starting torque 1,9/1,8 x Mn; Tilting moment 2,1/2,5 x Mn
Efficiency 88,3/93,6%
Power values fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø75 x 140 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU317.C3; Camp BS: 6317.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
- Foot mounting: Non-removable feet.