3AC ATEX motors KEMM
Ex2SIE-71-2A – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,37 kW (0,50 HP) |
| Rated speed | 2870 min⁻¹ |
| Rated torque | 1,2 Nm |
| Efficiency/cos φ | 70,5% / 0,80 |
| Rated current (400 V) | 0,95 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,90 |
| Locked Rotor Current Ratio (I)L/IN) | 5,20 |
| Breakdown Torque Ratio (T)BB/TN) | 2,20 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 15 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex2SIE-71-2B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,55 kW (0,75 HP) |
| Rated speed | 2850 min⁻¹ |
| Rated torque | 1,8 Nm |
| Efficiency/cos φ | 74,5% / 0,82 |
| Rated current (400 V) | 1,30 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,90 |
| Locked Rotor Current Ratio (I)L/IN) | 5,10 |
| Breakdown Torque Ratio (T)BB/TN) | 2,10 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 18 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex2SIE-71-4A – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,25 kW (0,33 HP) |
| Rated speed | 1410 min⁻¹ |
| Rated torque | 1,7 Nm |
| Efficiency/cos φ | 70,0% / 0,62 |
| Rated current (400 V) | 0,85 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,80 |
| Locked Rotor Current Ratio (I)L/IN) | 3,70 |
| Breakdown Torque Ratio (T)BB/TN) | 2,90 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 55 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex2SIE-71-4B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,37 kW (0,50 HP) |
| Rated speed | 1410 min⁻¹ |
| Rated torque | 2,5 Nm |
| Efficiency/cos φ | 72,5% / 0,64 |
| Rated current (400 V) | 1,15 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,90 |
| Locked Rotor Current Ratio (I)L/IN) | 4,10 |
| Breakdown Torque Ratio (T)BB/TN) | 3,10 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 34 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex2SIE-71-6A – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,18 kW (0,25 HP) |
| Rated speed | 910 min⁻¹ |
| Rated torque | 1,9 Nm |
| Efficiency/cos φ | 63,5% / 0,64 |
| Rated current (400 V) | 0,65 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,70 |
| Locked Rotor Current Ratio (I)L/IN) | 3,10 |
| Breakdown Torque Ratio (T)BB/TN) | 2,70 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 70 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex2SIE-71-6B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 0,25 kW (0,33 HP) |
| Rated speed | 910 min⁻¹ |
| Rated torque | 2,6 Nm |
| Efficiency/cos φ | 64,0% / 0,65 |
| Rated current (400 V) | 0,90 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,60 |
| Locked Rotor Current Ratio (I)L/IN) | 2,90 |
| Breakdown Torque Ratio (T)BB/TN) | 2,50 |
| Moment of Inertia J | kgm2 |
| Time tEE (T3) | 40 s |
| Ball bearing (DE / NDE) | 6203 2Z C3 / 6203 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 14 mm / 30 mm |
Ex3SIE-112M-2 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 4,00 kW (5,50 HP) |
| Rated speed | 2925 min⁻¹ |
| Rated torque | 13,0 Nm |
| Efficiency/cos φ | 88,1% / 0,89 |
| Rated current (400 V) | 7,40 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,30 |
| Locked Rotor Current Ratio (I)L/IN) | 8,40 |
| Breakdown Torque Ratio (T)BB/TN) | 3,20 |
| Moment of Inertia J | 0,007 kgm2 |
| Time tEE (T3) | 14 s |
| Ball bearing (DE / NDE) | 6306 2Z C3 / 6306 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 28 mm / 60 mm |
Ex3SIE-112M-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 4,00 kW (5,50 HP) |
| Rated speed | 1455 min⁻¹ |
| Rated torque | 26,3 Nm |
| Efficiency/cos φ | 88,6% / 0,80 |
| Rated current (400 V) | 8,10 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,10 |
| Locked Rotor Current Ratio (I)L/IN) | 6,90 |
| Breakdown Torque Ratio (T)BB/TN) | 3,00 |
| Moment of Inertia J | 0,011 kgm2 |
| Time tEE (T3) | 12 s |
| Ball bearing (DE / NDE) | 6306 2Z C3 / 6306 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 28 mm / 60 mm |
Ex3SIE-112M-6 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 2,20 kW (3,00 HP) |
| Rated speed | 965 min⁻¹ |
| Rated torque | 21,8 Nm |
| Efficiency/cos φ | 84,3% / 0,76 |
| Rated current (400 V) | 5,00 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,10 |
| Locked Rotor Current Ratio (I)L/IN) | 6,40 |
| Breakdown Torque Ratio (T)BB/TN) | 2,60 |
| Moment of Inertia J | 0,018 kgm2 |
| Time tEE (T3) | 23 s |
| Ball bearing (DE / NDE) | 6306 2Z C3 / 6306 2Z C3 |
| Motorhousing | Aluminium |