Torque Motor K Series
- Ideal für Wickler und Bahnspannungsregler
- Drehmomenteinstellung durch Änderung der Spannung
- Ausgangsleistung 3-40 W
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3.6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.64 N·m
60 Hz: 0.61 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.17 N·m
60 Hz: 0.19 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 4×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 25
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 4 N·m
60 Hz: 3.8 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.1 N·m
60 Hz: 1.2 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 193×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 18
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3.2 N·m
60 Hz: 3.1 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.87 N·m
60 Hz: 0.95 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 100×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.91 A / 99 W
Single-Phase 115 VAC / 60 Hz / 0.96 A / 109 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.55 A / 37 W
Single-Phase 115 VAC / 60 Hz / 0.59 A / 42 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC1.5 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 8 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 8 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 3.3 W (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60Hz: 3.3 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 35 mN·m (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 35 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 775×10⁻⁴ kg·m²
- Capacitor: Product name: CH110CFAUL2, Capacity: 11 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 15
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.7 N·m
60 Hz: 2.6 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.73 N·m
60 Hz: 0.79 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 69×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.91 A / 99 W
Single-Phase 115 VAC / 60 Hz / 0.96 A / 109 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.55 A / 37 W
Single-Phase 115 VAC / 60 Hz / 0.59 A / 42 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC1.5 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 8 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 6.9 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 3.3 W (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60Hz: 3.3 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 35 mN·m (Torque Setting VoltageDC1.5 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 35 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 775×10⁻⁴ kg·m²
- Capacitor: Product name: CH110CFAUL2, Capacity: 11 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 8 N·m
60 Hz: 8 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 5.9 N·m
60 Hz: 6.4 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 775×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 8 N·m
60 Hz: 8 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 4.8 N·m
60 Hz: 5.1 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 775×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 80 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.9 A / 89 W
Single-Phase 100 VAC / 60 Hz / 1.06 A / 106 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.55 A / 34 W
Single-Phase 100 VAC / 60 Hz / 0.74 A / 45 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 220 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 210 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 60 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 65 mN·m (Torque Setting VoltageDC1.6 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.2 N·m
60 Hz: 2.1 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.61 N·m
60 Hz: 0.66 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 10 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 12 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 2.3 W (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60Hz: 2.8 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 130 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 30 mN·m (Torque Setting VoltageDC1.9 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 30 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 48×10⁻⁴ kg·m²
- Capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.15 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1 N·m
60 Hz: 1 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.29 N·m
60 Hz: 0.33 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 11.3×10⁻⁴ kg·m²
- Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz / 0.4 A / 81 W
Single-Phase 220 VAC / 60 Hz / 0.4 A / 87 W
Single-Phase 230 VAC / 50 Hz / 0.44 A / 92 W
Single-Phase 230 VAC / 60 Hz / 0.42 A / 96 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 220 VAC / 50 Hz / 0.22 A / 31 W
Single-Phase 220 VAC / 60 Hz / 0.25 A / 34 W
Single-Phase 230 VAC / 50 Hz / 0.23 A / 35 W
Single-Phase 230 VAC / 60 Hz / 0.26 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1 N·m
60 Hz: 1.1 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.33 N·m
60 Hz: 0.4 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 220 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 11.3×10⁻⁴ kg·m²
- Capacitor: Product name: CH25BFAUL, Capacity: 2.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 75
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz / 0.4 A / 81 W
Single-Phase 220 VAC / 60 Hz / 0.4 A / 87 W
Single-Phase 230 VAC / 50 Hz / 0.44 A / 92 W
Single-Phase 230 VAC / 60 Hz / 0.42 A / 96 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 220 VAC / 50 Hz / 0.22 A / 31 W
Single-Phase 220 VAC / 60 Hz / 0.25 A / 34 W
Single-Phase 230 VAC / 50 Hz / 0.23 A / 35 W
Single-Phase 230 VAC / 60 Hz / 0.26 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 5 N·m
60 Hz: 5 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 2.2 N·m
60 Hz: 2.7 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 220 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 350×10⁻⁴ kg·m²
- Capacitor: Product name: CH25BFAUL, Capacity: 2.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 7.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.85 N·m
60 Hz: 0.85 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.24 N·m
60 Hz: 0.27 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 7.8×10⁻⁴ kg·m²
- Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 7.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz / 0.4 A / 81 W
Single-Phase 220 VAC / 60 Hz / 0.4 A / 87 W
Single-Phase 230 VAC / 50 Hz / 0.44 A / 92 W
Single-Phase 230 VAC / 60 Hz / 0.42 A / 96 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 220 VAC / 50 Hz / 0.22 A / 31 W
Single-Phase 220 VAC / 60 Hz / 0.25 A / 34 W
Single-Phase 230 VAC / 50 Hz / 0.23 A / 35 W
Single-Phase 230 VAC / 60 Hz / 0.26 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.85 N·m
60 Hz: 0.91 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.27 N·m
60 Hz: 0.33 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 220 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 7.8×10⁻⁴ kg·m²
- Capacitor: Product name: CH25BFAUL, Capacity: 2.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.68 N·m
60 Hz: 0.68 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.19 N·m
60 Hz: 0.22 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 5×10⁻⁴ kg·m²
- Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 60
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 5 N·m
60 Hz: 5 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.6 N·m
60 Hz: 1.8 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 350×10⁻⁴ kg·m²
- Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous
Single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz / 0.4 A / 81 W
Single-Phase 220 VAC / 60 Hz / 0.4 A / 87 W
Single-Phase 230 VAC / 50 Hz / 0.44 A / 92 W
Single-Phase 230 VAC / 60 Hz / 0.42 A / 96 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 220 VAC / 50 Hz / 0.22 A / 31 W
Single-Phase 220 VAC / 60 Hz / 0.25 A / 34 W
Single-Phase 230 VAC / 50 Hz / 0.23 A / 35 W
Single-Phase 230 VAC / 60 Hz / 0.26 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 150 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 45 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 55 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.34 N·m
60 Hz: 0.36 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.11 N·m
60 Hz: 0.13 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 220 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 230 VAC / 60 Hz: 8 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 220 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50Hz: 1.8 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60Hz: 2.6 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 87 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 220 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 220 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※)
Single-Phase 230 VAC / 50 Hz: 750 r/min / 24 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 230 VAC / 60 Hz: 900 r/min / 28 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 1.26×10⁻⁴ kg·m²
- Capacitor: Product name: CH25BFAUL, Capacity: 2.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 70 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 36
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.3 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz / 0.38 A / 74 W
Single-Phase 200 VAC / 60 Hz / 0.45 A / 89 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 200 VAC / 50 Hz / 0.23 A / 29 W
Single-Phase 200 VAC / 60 Hz / 0.31 A / 37 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 140 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 40 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 45 mN·m (Torque Setting VoltageDC1.3 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3.7 N·m
60 Hz: 3.7 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.1 N·m
60 Hz: 1.2 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 6 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 200 VAC / 60 Hz: 7.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 200 VAC / 50Hz: 1.6 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60Hz: 2 W (Torque Setting VoltageDC1.3 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 78 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 82 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 200 VAC / 50 Hz: 750 r/min / 21 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 200 VAC / 60 Hz: 900 r/min / 23 mN·m (Torque Setting VoltageDC1.3 VAC※) - Permissible Inertia J: 181×10⁻⁴ kg·m²
- Capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.65 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).