Torque Motor K Series
- Ideal für Wickler und Bahnspannungsregler
- Drehmomenteinstellung durch Änderung der Spannung
- Ausgangsleistung 3-40 W
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 100
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.2 N·m
60 Hz: 1.3 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 100
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 3 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 1.7 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.71 N·m
60 Hz: 0.71 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.18 N·m
60 Hz: 0.2 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 9.6×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.71 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.25 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 9.6×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.4 N·m
60 Hz: 1.6 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.8 N·m
60 Hz: 2 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 3 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 3 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 18
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1 N·m
60 Hz: 1 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.26 N·m
60 Hz: 0.29 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 20×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 25
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 1.3 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.46 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 38×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3.6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.2 N·m
60 Hz: 0.2 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.052 N·m
60 Hz: 0.058 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 0.8×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3.6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.2 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.073 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 0.8×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 36
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 1.8 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.66 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 80×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 50
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
Single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
Single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
Single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.3 N·m
60 Hz: 2.3 N·m - Gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.59 N·m
60 Hz: 0.66 N·m - Maximum Output Power (5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
Single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 50
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 2.3 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.83 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 60
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
Single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
Single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
Single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): Single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
Single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - Gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 2.8 N·m
- Gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.99 N·m
- Maximum Output Power (5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
Single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): Single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): Single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
Single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10<sup>-4</sup> kg·m<sup>2</sup>
- Capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).