4IK25GN-UW2T2 GENERAL MOTOR WK2 SERIES

  • Frame Size: 80 mm
  • Output Power: 25 W
  • Series: World K Series
  • Type: With Terminal Box
  • Gear Ratio: -
  • Time Rating: Continuous
  • Rotation Direction: Depends on the combination Gearhead.
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.113 A
    Three-Phase380 VAC / 60 Hz / 0.102 A
    Three-Phase400 VAC / 50 Hz / 0.116 A
    Three-Phase400 VAC / 60 Hz / 0.103 A
    Three-Phase415 VAC / 50 Hz / 0.118 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 270 mN·m
    Three-Phase 380 VAC / 60 Hz: 220 mN·m
    Three-Phase 400 VAC / 50 Hz: 270 mN·m
    Three-Phase 400 VAC / 60 Hz: 220 mN·m
    Three-Phase 415 VAC / 50 Hz: 270 mN·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 205 mN·m / 1200 r/min
    Three-Phase 380 VAC / 60 Hz: 170 mN·m / 1450 r/min
    Three-Phase 400 VAC / 50 Hz: 205 mN·m / 1200 r/min
    Three-Phase 400 VAC / 60 Hz: 170 mN·m / 1450 r/min
    Three-Phase 415 VAC / 50 Hz: 205 mN·m / 1200 r/min
  • The Speed When Installing Gearhead: Depends on the combination Gearhead.
  • Permissible Torque of Gearhead Output Shaft: Depends on the combination Gearhead.
  • Permissible Inertia J: Depends on the combination Gearhead.
  • Capacitor: -
  • Overheat Protective Device Type: Thermal protector (Automatic return type)
  • Mass: 1.7 kg
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.

[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
124,00 €
exkl. 19% USt. , zzgl. Versand
Stk
Passendes Getriebe