Zum Hauptinhalt springen Zur Suche springen Zum Menü springen

ORIENTAL MOTOR


  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: -
  • Time Rating: Continuous
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • Overheat Protective Device Type: Thermal protector
  • Mass: 5.0 kg
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-A
Versandgewicht:
6,50 kg
Artikelgewicht:
5,00 kg
210,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
    Three-Phase 380 VAC / 60 Hz: 8.1 N·m
    Three-Phase 400 VAC / 50 Hz: 9.7 N·m
    Three-Phase 400 VAC / 60 Hz: 8.1 N·m
    Three-Phase 415 VAC / 50 Hz: 9.7 N·m
  • Permissible Inertia J: 162×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
414,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
    Three-Phase 380 VAC / 60 Hz: 8.1 N·m
    Three-Phase 400 VAC / 50 Hz: 9.7 N·m
    Three-Phase 400 VAC / 60 Hz: 8.1 N·m
    Three-Phase 415 VAC / 50 Hz: 9.7 N·m
  • Permissible Inertia J: 162×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
407,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
    Three-Phase 380 VAC / 60 Hz: 51.5 N·m
    Three-Phase 400 VAC / 50 Hz: 51.5 N·m
    Three-Phase 400 VAC / 60 Hz: 51.5 N·m
    Three-Phase 415 VAC / 50 Hz: 51.5 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
432,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
    Three-Phase 380 VAC / 60 Hz: 51.5 N·m
    Three-Phase 400 VAC / 50 Hz: 51.5 N·m
    Three-Phase 400 VAC / 60 Hz: 51.5 N·m
    Three-Phase 415 VAC / 50 Hz: 51.5 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
426,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
351,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 11.9 N·m
    Three-Phase 380 VAC / 60 Hz: 10 N·m
    Three-Phase 400 VAC / 50 Hz: 11.9 N·m
    Three-Phase 400 VAC / 60 Hz: 10 N·m
    Three-Phase 415 VAC / 50 Hz: 11.9 N·m
  • Permissible Inertia J: 162×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
335,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
    Three-Phase 380 VAC / 60 Hz: 47 N·m
    Three-Phase 400 VAC / 50 Hz: 47 N·m
    Three-Phase 400 VAC / 60 Hz: 47 N·m
    Three-Phase 415 VAC / 50 Hz: 47 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
432,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
    Three-Phase 380 VAC / 60 Hz: 47 N·m
    Three-Phase 400 VAC / 50 Hz: 47 N·m
    Three-Phase 400 VAC / 60 Hz: 47 N·m
    Three-Phase 415 VAC / 50 Hz: 47 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
426,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
351,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
    Three-Phase 380 VAC / 60 Hz: 6.8 N·m
    Three-Phase 400 VAC / 50 Hz: 8 N·m
    Three-Phase 400 VAC / 60 Hz: 6.8 N·m
    Three-Phase 415 VAC / 50 Hz: 8 N·m
  • Permissible Inertia J: 112×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
414,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
    Three-Phase 380 VAC / 60 Hz: 6.8 N·m
    Three-Phase 400 VAC / 50 Hz: 8 N·m
    Three-Phase 400 VAC / 60 Hz: 6.8 N·m
    Three-Phase 415 VAC / 50 Hz: 8 N·m
  • Permissible Inertia J: 112×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
407,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.9 N·m
    Three-Phase 380 VAC / 60 Hz: 8.4 N·m
    Three-Phase 400 VAC / 50 Hz: 9.9 N·m
    Three-Phase 400 VAC / 60 Hz: 8.4 N·m
    Three-Phase 415 VAC / 50 Hz: 9.9 N·m
  • Permissible Inertia J: 112×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
335,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
    Three-Phase 380 VAC / 60 Hz: 5.4 N·m
    Three-Phase 400 VAC / 50 Hz: 6.4 N·m
    Three-Phase 400 VAC / 60 Hz: 5.4 N·m
    Three-Phase 415 VAC / 50 Hz: 6.4 N·m
  • Permissible Inertia J: 72×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
414,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
    Three-Phase 380 VAC / 60 Hz: 5.4 N·m
    Three-Phase 400 VAC / 50 Hz: 6.4 N·m
    Three-Phase 400 VAC / 60 Hz: 5.4 N·m
    Three-Phase 415 VAC / 50 Hz: 6.4 N·m
  • Permissible Inertia J: 72×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
407,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
    Three-Phase 380 VAC / 60 Hz: 43 N·m
    Three-Phase 400 VAC / 50 Hz: 43 N·m
    Three-Phase 400 VAC / 60 Hz: 43 N·m
    Three-Phase 415 VAC / 50 Hz: 43 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
432,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
    Three-Phase 380 VAC / 60 Hz: 43 N·m
    Three-Phase 400 VAC / 50 Hz: 43 N·m
    Three-Phase 400 VAC / 60 Hz: 43 N·m
    Three-Phase 415 VAC / 50 Hz: 43 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
426,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
351,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 7.9 N·m
    Three-Phase 380 VAC / 60 Hz: 6.7 N·m
    Three-Phase 400 VAC / 50 Hz: 7.9 N·m
    Three-Phase 400 VAC / 60 Hz: 6.7 N·m
    Three-Phase 415 VAC / 50 Hz: 7.9 N·m
  • Permissible Inertia J: 72×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
335,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
    Three-Phase 380 VAC / 60 Hz: 360 r/min
    Three-Phase 400 VAC / 50 Hz: 300 r/min
    Three-Phase 400 VAC / 60 Hz: 360 r/min
    Three-Phase 415 VAC / 50 Hz: 300 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 5.4 N·m
    Three-Phase 380 VAC / 60 Hz: 4.5 N·m
    Three-Phase 400 VAC / 50 Hz: 5.4 N·m
    Three-Phase 400 VAC / 60 Hz: 4.5 N·m
    Three-Phase 415 VAC / 50 Hz: 5.4 N·m
  • Permissible Inertia J: 50×10<sup>-4</sup> kg·m<sup>2</sup>
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-5RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
414,00 € *
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen