ORIENTAL MOTOR
Artikel 1 - 20 von 120
• Description of Specification Items
- Frame Size: 90 mm
- Output Power: 90 W
- Type: Cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Electromagnetic Brake: Equipped
- Time Rating: Continuous
- Rotation Direction: Depends on the combination Gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.64 A
Three-Phase 200 VAC / 60 Hz / 0.59 A
Three-Phase 220 VAC / 60 Hz / 0.6 A
Three-Phase 230 VAC / 60 Hz / 0.61 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 850 mN·m
Three-Phase 200 VAC / 60 Hz: 700 mN·m
Three-Phase 220 VAC / 60 Hz: 700 mN·m
Three-Phase 230 VAC / 60 Hz: 700 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 680 mN·m / 1300 r/min
Three-Phase 200 VAC / 60 Hz: 570 mN·m / 1550 r/min
Three-Phase 220 VAC / 60 Hz: 570 mN·m / 1600 r/min
Three-Phase 230 VAC / 60 Hz: 570 mN·m / 1600 r/min - The Speed When Installing Gearhead: Depends on the combination Gearhead.
- Permissible Torque of Gearhead Output Shaft: Depends on the combination Gearhead.
- Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.07 A / 10 W
Single-Phase 200 VAC / 60 Hz / 0.07 A / 10 W
Single-Phase 220 VAC / 60 Hz / 0.07 A / 10 W
Single-Phase 230 VAC / 60 Hz / 0.07 A / 10 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Capacitor: -
- Overheat Protective Device Type: Thermal protector (Automatic return type)
- Mass: 3.9 kg
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
• It does no built-in simple brake similar to reversible motor
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.
• The product name written on the motor nameplate is 5IK90GU-AWT. The suffix of the product name above indicates the type of capacitor.
U: Single-phase 110 VAC/115 VAC capacitor included (this product)
J: Single-phase 100 VAC capacitor included. (5IK90GU-AWTJ)
- Frame Size: 90 mm
- Output Power: 90 W
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination Gearhead.
- Voltage/ Frequency/ Current: Single-Phase 110 VAC / 60 Hz / 1.45 A
Single-Phase 115 VAC / 60 Hz / 1.44 A - Starting Torque (Motor Shaft): Single-Phase 110 VAC / 60 Hz: 450 mN·m
Single-Phase 115 VAC / 60 Hz: 450 mN·m - Rated torque/ Rated Speed (Motor Shaft): Single-Phase 110 VAC / 60 Hz: 585 mN·m / 1500 r/min
Single-Phase 115 VAC / 60 Hz: 585 mN·m / 1500 r/min - The Speed When Installing Gearhead: Depends on the combination Gearhead.
- Permissible Torque of Gearhead Output Shaft: Depends on the combination Gearhead.
- Permissible Inertia J: Depends on the combination Gearhead.
- Capacitor: Product name: CH200CFAUL2, Capacity: 20 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector (Automatic return type)
- Mass: 3.3 kg
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
• The product name listed on the motor nameplate does not include the code (U) that indicates the type of capacitor.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.

- Frame Size: 90 mm
- Output Power: 90 W
- Type: Lead Wire Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gear head.
- Voltage/ Frequency/ Current: Single-Phase 100 VAC / 50 Hz / 1.64 A
Single-Phase 100 VAC / 60 Hz / 1.67 A - Starting Torque (Motor Shaft): Single-Phase 100 VAC / 50 Hz: 450 mN·m
Single-Phase 100 VAC / 60 Hz: 450 mN·m - Rated torque/ Rated Speed (Motor Shaft): Single-Phase 100 VAC / 50 Hz: 700 mN·m / 1250 r/min
Single-Phase 100 VAC / 60 Hz: 585 mN·m / 1500 r/min - The Speed When Installing Gearhead: Depends on the combination gear head.
- Permissible Torque of Gearhead Output Shaft: Depends on the combination gear head.
- Permissible Inertia J: Depends on the combination gear head.
- Capacitor: Product name: CH280CFAUL2, Capacity: 28 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector (Automatic return type)
The product name written on the motor nameplate is 5IK90GU-AW. The suffix of the product name above indicates the type of capacitor.
J: Single-phase 100 VAC capacitor included (this product)
U: Single-phase 110 VAC/115 VAC capacitor included. (5IK90GU-AWU)
- Frame Size: 90 mm
- Output Power: 90 W
- Series: World K Series
- Type: Lead Wire Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination Gearhead.
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.39 A
Three-Phase380 VAC / 60 Hz / 0.33 A
Three-Phase400 VAC / 50 Hz / 0.41 A
Three-Phase400 VAC / 60 Hz / 0.34 A
Three-Phase415 VAC / 50 Hz / 0.44 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 850 mN·m
Three-Phase 380 VAC / 60 Hz: 700 mN·m
Three-Phase 400 VAC / 50 Hz: 850 mN·m
Three-Phase 400 VAC / 60 Hz: 700 mN·m
Three-Phase 415 VAC / 50 Hz: 850 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 680 mN·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 570 mN·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 680 mN·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 570 mN·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 680 mN·m / 1300 r/min - The Speed When Installing Gearhead: Depends on the combination Gearhead.
- Permissible Torque of Gearhead Output Shaft: Depends on the combination Gearhead.
- Permissible Inertia J: Depends on the combination Gearhead.
- Capacitor: -
- Overheat Protective Device Type: Thermal protector (Automatic return type)
- Mass: 3.2 kg
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Ausgangsleistung: 90 W
- Drehzahl: 1500 min-1
- Motor-Rahmengröße: 90 mm
- Schutzart IP20
- RoHS-konform
- inkl. Kodensator mit Schutzkappe bei Wechselstrommotoren
- inkl. Befestigungsschrauben, Unterlegscheiben und Muttern
Die Drehzahl wird berechnet, indem die Synchrondrehzahl des Motors (50 Hz: 1500 min-1, 60 Hz: 1800 min-1) durch die Getriebeuntersetzung geteilt wird.
Je nach Last ist die tatsächliche Drehzahl 2-20 % niedriger als der hier aufgeführte Wert.
- Drehzahl: 1500 min-1
- Motor-Rahmengröße: 90 mm
- Schutzart IP20
- RoHS-konform
- inkl. Kodensator mit Schutzkappe bei Wechselstrommotoren
- inkl. Befestigungsschrauben, Unterlegscheiben und Muttern
Die Drehzahl wird berechnet, indem die Synchrondrehzahl des Motors (50 Hz: 1500 min-1, 60 Hz: 1800 min-1) durch die Getriebeuntersetzung geteilt wird.
Je nach Last ist die tatsächliche Drehzahl 2-20 % niedriger als der hier aufgeführte Wert.
- Ausgangsleistung: 90 W
- Drehzahl: 1500 min-1
- Motor-Rahmengröße: 90 mm
- Schutzart IP20
- RoHS-konform
- inkl. Kodensator mit Schutzkappe bei Wechselstrommotoren
- inkl. Befestigungsschrauben, Unterlegscheiben und Muttern
Die Drehzahl wird berechnet, indem die Synchrondrehzahl des Motors (50 Hz: 1500 min-1, 60 Hz: 1800 min-1) durch die Getriebeuntersetzung geteilt wird.
Je nach Last ist die tatsächliche Drehzahl 2-20 % niedriger als der hier aufgeführte Wert.
- Drehzahl: 1500 min-1
- Motor-Rahmengröße: 90 mm
- Schutzart IP20
- RoHS-konform
- inkl. Kodensator mit Schutzkappe bei Wechselstrommotoren
- inkl. Befestigungsschrauben, Unterlegscheiben und Muttern
Die Drehzahl wird berechnet, indem die Synchrondrehzahl des Motors (50 Hz: 1500 min-1, 60 Hz: 1800 min-1) durch die Getriebeuntersetzung geteilt wird.
Je nach Last ist die tatsächliche Drehzahl 2-20 % niedriger als der hier aufgeführte Wert.
Artikel 1 - 20 von 120