ORIENTAL MOTOR
Artikel 1 - 9 von 9
Leistung:
150 Watt
Leistung:
60 Watt
Produktart:
Motor
Produktart:
mit Bremse
Alle Filter zurücksetzen
• Description of Specification Items
- Frame Size: 90 mm
- Output Power: 60 W
- Type: Cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Electromagnetic Brake: Equipped
- Time Rating: Continuous
- Rotation Direction: Depends on the combination Gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.5 A
Three-Phase 200 VAC / 60 Hz / 0.43 A
Three-Phase 220 VAC / 60 Hz / 0.45 A
Three-Phase 230 VAC / 60 Hz / 0.46 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m
Three-Phase 220 VAC / 60 Hz: 500 mN·m
Three-Phase 230 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 450 mN·m / 1300 r/min
Three-Phase 200 VAC / 60 Hz: 380 mN·m / 1550 r/min
Three-Phase 220 VAC / 60 Hz: 380 mN·m / 1600 r/min
Three-Phase 230 VAC / 60 Hz: 380 mN·m / 1600 r/min - The Speed When Installing Gearhead: Depends on the combination Gearhead.
- Permissible Torque of Gearhead Output Shaft: Depends on the combination Gearhead.
- Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.07 A / 10 W
Single-Phase 200 VAC / 60 Hz / 0.07 A / 10 W
Single-Phase 220 VAC / 60 Hz / 0.07 A / 10 W
Single-Phase 230 VAC / 60 Hz / 0.07 A / 10 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Capacitor: -
- Overheat Protective Device Type: Thermal protector (Automatic return type)
- Mass: 3.4 kg
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
• It does no built-in simple brake similar to reversible motor
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: Cable Type
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 0.37 A
Three-Phase 220 VAC / 60 Hz / 0.33 A
Three-Phase 230 VAC VAC / 50 Hz / 0.38 A
Three-Phase 230 VAC VAC / 60 Hz / 0.33 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 600 mN·m
Three-Phase 220 VAC / 60 Hz: 500 mN·m
Three-Phase 230 VAC VAC / 50 Hz: 600 mN·m
Three-Phase 230 VAC VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 220 VAC / 60 Hz: 350 mN·m / 1670 r/min
Three-Phase 230 VAC VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 230 VAC VAC / 60 Hz: 350 mN·m / 1670 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 220 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 220 VAC / 60 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: With Terminal Box
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 0.37 A
Three-Phase 220 VAC / 60 Hz / 0.33 A
Three-Phase 230 VAC VAC / 50 Hz / 0.38 A
Three-Phase 230 VAC VAC / 60 Hz / 0.33 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 600 mN·m
Three-Phase 220 VAC / 60 Hz: 500 mN·m
Three-Phase 230 VAC VAC / 50 Hz: 600 mN·m
Three-Phase 230 VAC VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 220 VAC / 60 Hz: 350 mN·m / 1670 r/min
Three-Phase 230 VAC VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 230 VAC VAC / 60 Hz: 350 mN·m / 1670 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 220 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 220 VAC / 60 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: Cable Type
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: With Terminal Box
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: Cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 0.37 A
Three-Phase 220 VAC / 60 Hz / 0.33 A
Three-Phase 230 VAC VAC / 50 Hz / 0.38 A
Three-Phase 230 VAC VAC / 60 Hz / 0.33 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 600 mN·m
Three-Phase 220 VAC / 60 Hz: 500 mN·m
Three-Phase 230 VAC VAC / 50 Hz: 600 mN·m
Three-Phase 230 VAC VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 220 VAC / 60 Hz: 350 mN·m / 1670 r/min
Three-Phase 230 VAC VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 230 VAC VAC / 60 Hz: 350 mN·m / 1670 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 220 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 220 VAC / 60 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 0.37 A
Three-Phase 220 VAC / 60 Hz / 0.33 A
Three-Phase 230 VAC VAC / 50 Hz / 0.38 A
Three-Phase 230 VAC VAC / 60 Hz / 0.33 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 600 mN·m
Three-Phase 220 VAC / 60 Hz: 500 mN·m
Three-Phase 230 VAC VAC / 50 Hz: 600 mN·m
Three-Phase 230 VAC VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 220 VAC / 60 Hz: 350 mN·m / 1670 r/min
Three-Phase 230 VAC VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 230 VAC VAC / 60 Hz: 350 mN·m / 1670 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 220 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 220 VAC / 60 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 230 VAC VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: Cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- Series: KIIS Series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: Single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
Single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
Artikel 1 - 9 von 9