Zum Hauptinhalt springen Zur Suche springen Zum Menü springen

ORIENTAL MOTOR


  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: -
  • Time Rating: Continuous
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • Overheat Protective Device Type: Thermal protector
  • Mass: 5.0 kg
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-A
Versandgewicht:
6,50 kg
Artikelgewicht:
5,00 kg
249,90 € * 210,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
    Three-Phase 380 VAC / 60 Hz: 8.1 N·m
    Three-Phase 400 VAC / 50 Hz: 9.7 N·m
    Three-Phase 400 VAC / 60 Hz: 8.1 N·m
    Three-Phase 415 VAC / 50 Hz: 9.7 N·m
  • Permissible Inertia J: 162×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
    Three-Phase 380 VAC / 60 Hz: 8.1 N·m
    Three-Phase 400 VAC / 50 Hz: 9.7 N·m
    Three-Phase 400 VAC / 60 Hz: 8.1 N·m
    Three-Phase 415 VAC / 50 Hz: 9.7 N·m
  • Permissible Inertia J: 162×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
    Three-Phase 380 VAC / 60 Hz: 51.5 N·m
    Three-Phase 400 VAC / 50 Hz: 51.5 N·m
    Three-Phase 400 VAC / 60 Hz: 51.5 N·m
    Three-Phase 415 VAC / 50 Hz: 51.5 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
    Three-Phase 380 VAC / 60 Hz: 51.5 N·m
    Three-Phase 400 VAC / 50 Hz: 51.5 N·m
    Three-Phase 400 VAC / 60 Hz: 51.5 N·m
    Three-Phase 415 VAC / 50 Hz: 51.5 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 90
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
    Three-Phase 380 VAC / 60 Hz: 20 r/min
    Three-Phase 400 VAC / 50 Hz: 17 r/min
    Three-Phase 400 VAC / 60 Hz: 20 r/min
    Three-Phase 415 VAC / 50 Hz: 17 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-90
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 9
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
    Three-Phase 380 VAC / 60 Hz: 200 r/min
    Three-Phase 400 VAC / 50 Hz: 167 r/min
    Three-Phase 400 VAC / 60 Hz: 200 r/min
    Three-Phase 415 VAC / 50 Hz: 167 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 11.9 N·m
    Three-Phase 380 VAC / 60 Hz: 10 N·m
    Three-Phase 400 VAC / 50 Hz: 11.9 N·m
    Three-Phase 400 VAC / 60 Hz: 10 N·m
    Three-Phase 415 VAC / 50 Hz: 11.9 N·m
  • Permissible Inertia J: 162×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-9
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
    Three-Phase 380 VAC / 60 Hz: 47 N·m
    Three-Phase 400 VAC / 50 Hz: 47 N·m
    Three-Phase 400 VAC / 60 Hz: 47 N·m
    Three-Phase 415 VAC / 50 Hz: 47 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
    Three-Phase 380 VAC / 60 Hz: 47 N·m
    Three-Phase 400 VAC / 50 Hz: 47 N·m
    Three-Phase 400 VAC / 60 Hz: 47 N·m
    Three-Phase 415 VAC / 50 Hz: 47 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 75
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
    Three-Phase 380 VAC / 60 Hz: 24 r/min
    Three-Phase 400 VAC / 50 Hz: 20 r/min
    Three-Phase 400 VAC / 60 Hz: 24 r/min
    Three-Phase 415 VAC / 50 Hz: 20 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-75
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
    Three-Phase 380 VAC / 60 Hz: 6.8 N·m
    Three-Phase 400 VAC / 50 Hz: 8 N·m
    Three-Phase 400 VAC / 60 Hz: 6.8 N·m
    Three-Phase 415 VAC / 50 Hz: 8 N·m
  • Permissible Inertia J: 112×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
    Three-Phase 380 VAC / 60 Hz: 6.8 N·m
    Three-Phase 400 VAC / 50 Hz: 8 N·m
    Three-Phase 400 VAC / 60 Hz: 6.8 N·m
    Three-Phase 415 VAC / 50 Hz: 8 N·m
  • Permissible Inertia J: 112×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 7.5
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
    Three-Phase 380 VAC / 60 Hz: 240 r/min
    Three-Phase 400 VAC / 50 Hz: 200 r/min
    Three-Phase 400 VAC / 60 Hz: 240 r/min
    Three-Phase 415 VAC / 50 Hz: 200 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.9 N·m
    Three-Phase 380 VAC / 60 Hz: 8.4 N·m
    Three-Phase 400 VAC / 50 Hz: 9.9 N·m
    Three-Phase 400 VAC / 60 Hz: 8.4 N·m
    Three-Phase 415 VAC / 50 Hz: 9.9 N·m
  • Permissible Inertia J: 112×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-7.5
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
    Three-Phase 380 VAC / 60 Hz: 5.4 N·m
    Three-Phase 400 VAC / 50 Hz: 6.4 N·m
    Three-Phase 400 VAC / 60 Hz: 5.4 N·m
    Three-Phase 415 VAC / 50 Hz: 6.4 N·m
  • Permissible Inertia J: 72×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
    Three-Phase 380 VAC / 60 Hz: 5.4 N·m
    Three-Phase 400 VAC / 50 Hz: 6.4 N·m
    Three-Phase 400 VAC / 60 Hz: 5.4 N·m
    Three-Phase 415 VAC / 50 Hz: 6.4 N·m
  • Permissible Inertia J: 72×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
    Three-Phase 380 VAC / 60 Hz: 43 N·m
    Three-Phase 400 VAC / 50 Hz: 43 N·m
    Three-Phase 400 VAC / 60 Hz: 43 N·m
    Three-Phase 415 VAC / 50 Hz: 43 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
    Three-Phase 380 VAC / 60 Hz: 43 N·m
    Three-Phase 400 VAC / 50 Hz: 43 N·m
    Three-Phase 400 VAC / 60 Hz: 43 N·m
    Three-Phase 415 VAC / 50 Hz: 43 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 60
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
    Three-Phase 380 VAC / 60 Hz: 30 r/min
    Three-Phase 400 VAC / 50 Hz: 25 r/min
    Three-Phase 400 VAC / 60 Hz: 30 r/min
    Three-Phase 415 VAC / 50 Hz: 25 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-60
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 6
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
    Three-Phase 380 VAC / 60 Hz: 300 r/min
    Three-Phase 400 VAC / 50 Hz: 250 r/min
    Three-Phase 400 VAC / 60 Hz: 300 r/min
    Three-Phase 415 VAC / 50 Hz: 250 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 7.9 N·m
    Three-Phase 380 VAC / 60 Hz: 6.7 N·m
    Three-Phase 400 VAC / 50 Hz: 7.9 N·m
    Three-Phase 400 VAC / 60 Hz: 6.7 N·m
    Three-Phase 415 VAC / 50 Hz: 7.9 N·m
  • Permissible Inertia J: 72×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-6
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
    Three-Phase 380 VAC / 60 Hz: 360 r/min
    Three-Phase 400 VAC / 50 Hz: 300 r/min
    Three-Phase 400 VAC / 60 Hz: 360 r/min
    Three-Phase 415 VAC / 50 Hz: 300 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 5.4 N·m
    Three-Phase 380 VAC / 60 Hz: 4.5 N·m
    Three-Phase 400 VAC / 50 Hz: 5.4 N·m
    Three-Phase 400 VAC / 60 Hz: 4.5 N·m
    Three-Phase 415 VAC / 50 Hz: 5.4 N·m
  • Permissible Inertia J: 50×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-5RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 5
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
    Three-Phase 380 VAC / 60 Hz: 360 r/min
    Three-Phase 400 VAC / 50 Hz: 300 r/min
    Three-Phase 400 VAC / 60 Hz: 360 r/min
    Three-Phase 415 VAC / 50 Hz: 300 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 5.4 N·m
    Three-Phase 380 VAC / 60 Hz: 4.5 N·m
    Three-Phase 400 VAC / 50 Hz: 5.4 N·m
    Three-Phase 400 VAC / 60 Hz: 4.5 N·m
    Three-Phase 415 VAC / 50 Hz: 5.4 N·m
  • Permissible Inertia J: 50×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-5RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 50
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
    Three-Phase 380 VAC / 60 Hz: 36 r/min
    Three-Phase 400 VAC / 50 Hz: 30 r/min
    Three-Phase 400 VAC / 60 Hz: 36 r/min
    Three-Phase 415 VAC / 50 Hz: 30 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-50RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 50
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
    Three-Phase 380 VAC / 60 Hz: 36 r/min
    Three-Phase 400 VAC / 50 Hz: 30 r/min
    Three-Phase 400 VAC / 60 Hz: 36 r/min
    Three-Phase 415 VAC / 50 Hz: 30 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-50RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 50
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
    Three-Phase 380 VAC / 60 Hz: 36 r/min
    Three-Phase 400 VAC / 50 Hz: 30 r/min
    Three-Phase 400 VAC / 60 Hz: 36 r/min
    Three-Phase 415 VAC / 50 Hz: 30 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-50
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 5
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
    Three-Phase 380 VAC / 60 Hz: 360 r/min
    Three-Phase 400 VAC / 50 Hz: 300 r/min
    Three-Phase 400 VAC / 60 Hz: 360 r/min
    Three-Phase 415 VAC / 50 Hz: 300 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.6 N·m
    Three-Phase 380 VAC / 60 Hz: 5.6 N·m
    Three-Phase 400 VAC / 50 Hz: 6.6 N·m
    Three-Phase 400 VAC / 60 Hz: 5.6 N·m
    Three-Phase 415 VAC / 50 Hz: 6.6 N·m
  • Permissible Inertia J: 50×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-5
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 36
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
    Three-Phase 380 VAC / 60 Hz: 50 r/min
    Three-Phase 400 VAC / 50 Hz: 42 r/min
    Three-Phase 400 VAC / 60 Hz: 50 r/min
    Three-Phase 415 VAC / 50 Hz: 42 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 36 N·m
    Three-Phase 380 VAC / 60 Hz: 32.6 N·m
    Three-Phase 400 VAC / 50 Hz: 36 N·m
    Three-Phase 400 VAC / 60 Hz: 32.6 N·m
    Three-Phase 415 VAC / 50 Hz: 36 N·m
  • Permissible Inertia J: 2592×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-36RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 36
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
    Three-Phase 380 VAC / 60 Hz: 50 r/min
    Three-Phase 400 VAC / 50 Hz: 42 r/min
    Three-Phase 400 VAC / 60 Hz: 50 r/min
    Three-Phase 415 VAC / 50 Hz: 42 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 36 N·m
    Three-Phase 380 VAC / 60 Hz: 32.6 N·m
    Three-Phase 400 VAC / 50 Hz: 36 N·m
    Three-Phase 400 VAC / 60 Hz: 32.6 N·m
    Three-Phase 415 VAC / 50 Hz: 36 N·m
  • Permissible Inertia J: 2592×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-36RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 36
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
    Three-Phase 380 VAC / 60 Hz: 50 r/min
    Three-Phase 400 VAC / 50 Hz: 42 r/min
    Three-Phase 400 VAC / 60 Hz: 50 r/min
    Three-Phase 415 VAC / 50 Hz: 42 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 38.4 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 38.4 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 2592×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-36
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
406,98 € * 342,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 30
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 50 r/min
    Three-Phase 380 VAC / 60 Hz: 60 r/min
    Three-Phase 400 VAC / 50 Hz: 50 r/min
    Three-Phase 400 VAC / 60 Hz: 60 r/min
    Three-Phase 415 VAC / 50 Hz: 50 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 32.2 N·m
    Three-Phase 380 VAC / 60 Hz: 27.2 N·m
    Three-Phase 400 VAC / 50 Hz: 32.2 N·m
    Three-Phase 400 VAC / 60 Hz: 27.2 N·m
    Three-Phase 415 VAC / 50 Hz: 32.2 N·m
  • Permissible Inertia J: 1800×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-30RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 30
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 50 r/min
    Three-Phase 380 VAC / 60 Hz: 60 r/min
    Three-Phase 400 VAC / 50 Hz: 50 r/min
    Three-Phase 400 VAC / 60 Hz: 60 r/min
    Three-Phase 415 VAC / 50 Hz: 50 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 32.2 N·m
    Three-Phase 380 VAC / 60 Hz: 27.2 N·m
    Three-Phase 400 VAC / 50 Hz: 32.2 N·m
    Three-Phase 400 VAC / 60 Hz: 27.2 N·m
    Three-Phase 415 VAC / 50 Hz: 32.2 N·m
  • Permissible Inertia J: 1800×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-30RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 30
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 50 r/min
    Three-Phase 380 VAC / 60 Hz: 60 r/min
    Three-Phase 400 VAC / 50 Hz: 50 r/min
    Three-Phase 400 VAC / 60 Hz: 60 r/min
    Three-Phase 415 VAC / 50 Hz: 50 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 37.9 N·m
    Three-Phase 380 VAC / 60 Hz: 32 N·m
    Three-Phase 400 VAC / 50 Hz: 37.9 N·m
    Three-Phase 400 VAC / 60 Hz: 32 N·m
    Three-Phase 415 VAC / 50 Hz: 37.9 N·m
  • Permissible Inertia J: 1800×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-30
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
406,98 € * 342,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 3.6
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 417 r/min
    Three-Phase 380 VAC / 60 Hz: 500 r/min
    Three-Phase 400 VAC / 50 Hz: 417 r/min
    Three-Phase 400 VAC / 60 Hz: 500 r/min
    Three-Phase 415 VAC / 50 Hz: 417 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 4.8 N·m
    Three-Phase 380 VAC / 60 Hz: 4 N·m
    Three-Phase 400 VAC / 50 Hz: 4.8 N·m
    Three-Phase 400 VAC / 60 Hz: 4 N·m
    Three-Phase 415 VAC / 50 Hz: 4.8 N·m
  • Permissible Inertia J: 25×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-3.6
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 3
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 500 r/min
    Three-Phase 380 VAC / 60 Hz: 600 r/min
    Three-Phase 400 VAC / 50 Hz: 500 r/min
    Three-Phase 400 VAC / 60 Hz: 600 r/min
    Three-Phase 415 VAC / 50 Hz: 500 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 4 N·m
    Three-Phase 380 VAC / 60 Hz: 3.3 N·m
    Three-Phase 400 VAC / 50 Hz: 4 N·m
    Three-Phase 400 VAC / 60 Hz: 3.3 N·m
    Three-Phase 415 VAC / 50 Hz: 4 N·m
  • Permissible Inertia J: 18×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-3
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
398,65 € * 335,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 25
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 60 r/min
    Three-Phase 380 VAC / 60 Hz: 72 r/min
    Three-Phase 400 VAC / 50 Hz: 60 r/min
    Three-Phase 400 VAC / 60 Hz: 72 r/min
    Three-Phase 415 VAC / 50 Hz: 60 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 26.8 N·m
    Three-Phase 380 VAC / 60 Hz: 22.6 N·m
    Three-Phase 400 VAC / 50 Hz: 26.8 N·m
    Three-Phase 400 VAC / 60 Hz: 22.6 N·m
    Three-Phase 415 VAC / 50 Hz: 26.8 N·m
  • Permissible Inertia J: 1250×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-25RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 25
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 60 r/min
    Three-Phase 380 VAC / 60 Hz: 72 r/min
    Three-Phase 400 VAC / 50 Hz: 60 r/min
    Three-Phase 400 VAC / 60 Hz: 72 r/min
    Three-Phase 415 VAC / 50 Hz: 60 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 26.8 N·m
    Three-Phase 380 VAC / 60 Hz: 22.6 N·m
    Three-Phase 400 VAC / 50 Hz: 26.8 N·m
    Three-Phase 400 VAC / 60 Hz: 22.6 N·m
    Three-Phase 415 VAC / 50 Hz: 26.8 N·m
  • Permissible Inertia J: 1250×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-25RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 25
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 60 r/min
    Three-Phase 380 VAC / 60 Hz: 72 r/min
    Three-Phase 400 VAC / 50 Hz: 60 r/min
    Three-Phase 400 VAC / 60 Hz: 72 r/min
    Three-Phase 415 VAC / 50 Hz: 60 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 31.6 N·m
    Three-Phase 380 VAC / 60 Hz: 26.7 N·m
    Three-Phase 400 VAC / 50 Hz: 31.6 N·m
    Three-Phase 400 VAC / 60 Hz: 26.7 N·m
    Three-Phase 415 VAC / 50 Hz: 31.6 N·m
  • Permissible Inertia J: 1250×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-25
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
406,98 € * 342,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 18
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 83 r/min
    Three-Phase 380 VAC / 60 Hz: 100 r/min
    Three-Phase 400 VAC / 50 Hz: 83 r/min
    Three-Phase 400 VAC / 60 Hz: 100 r/min
    Three-Phase 415 VAC / 50 Hz: 83 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 19.3 N·m
    Three-Phase 380 VAC / 60 Hz: 16.3 N·m
    Three-Phase 400 VAC / 50 Hz: 19.3 N·m
    Three-Phase 400 VAC / 60 Hz: 16.3 N·m
    Three-Phase 415 VAC / 50 Hz: 19.3 N·m
  • Permissible Inertia J: 648×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-18RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 18
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 83 r/min
    Three-Phase 380 VAC / 60 Hz: 100 r/min
    Three-Phase 400 VAC / 50 Hz: 83 r/min
    Three-Phase 400 VAC / 60 Hz: 100 r/min
    Three-Phase 415 VAC / 50 Hz: 83 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 19.3 N·m
    Three-Phase 380 VAC / 60 Hz: 16.3 N·m
    Three-Phase 400 VAC / 50 Hz: 19.3 N·m
    Three-Phase 400 VAC / 60 Hz: 16.3 N·m
    Three-Phase 415 VAC / 50 Hz: 19.3 N·m
  • Permissible Inertia J: 648×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-18RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 180
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 8.3 r/min
    Three-Phase 380 VAC / 60 Hz: 10 r/min
    Three-Phase 400 VAC / 50 Hz: 8.3 r/min
    Three-Phase 400 VAC / 60 Hz: 10 r/min
    Three-Phase 415 VAC / 50 Hz: 8.3 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-180RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 180
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 8.3 r/min
    Three-Phase 380 VAC / 60 Hz: 10 r/min
    Three-Phase 400 VAC / 50 Hz: 8.3 r/min
    Three-Phase 400 VAC / 60 Hz: 10 r/min
    Three-Phase 415 VAC / 50 Hz: 8.3 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-180RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 180
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 8.3 r/min
    Three-Phase 380 VAC / 60 Hz: 10 r/min
    Three-Phase 400 VAC / 50 Hz: 8.3 r/min
    Three-Phase 400 VAC / 60 Hz: 10 r/min
    Three-Phase 415 VAC / 50 Hz: 8.3 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-180
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 18
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 83 r/min
    Three-Phase 380 VAC / 60 Hz: 100 r/min
    Three-Phase 400 VAC / 50 Hz: 83 r/min
    Three-Phase 400 VAC / 60 Hz: 100 r/min
    Three-Phase 415 VAC / 50 Hz: 83 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 22.8 N·m
    Three-Phase 380 VAC / 60 Hz: 19.2 N·m
    Three-Phase 400 VAC / 50 Hz: 22.8 N·m
    Three-Phase 400 VAC / 60 Hz: 19.2 N·m
    Three-Phase 415 VAC / 50 Hz: 22.8 N·m
  • Permissible Inertia J: 648×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-18
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
406,98 € * 342,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 15
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 100 r/min
    Three-Phase 380 VAC / 60 Hz: 120 r/min
    Three-Phase 400 VAC / 50 Hz: 100 r/min
    Three-Phase 400 VAC / 60 Hz: 120 r/min
    Three-Phase 415 VAC / 50 Hz: 100 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 16.1 N·m
    Three-Phase 380 VAC / 60 Hz: 13.6 N·m
    Three-Phase 400 VAC / 50 Hz: 16.1 N·m
    Three-Phase 400 VAC / 60 Hz: 13.6 N·m
    Three-Phase 415 VAC / 50 Hz: 16.1 N·m
  • Permissible Inertia J: 450×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-15RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
492,66 € * 414,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 15
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 100 r/min
    Three-Phase 380 VAC / 60 Hz: 120 r/min
    Three-Phase 400 VAC / 50 Hz: 100 r/min
    Three-Phase 400 VAC / 60 Hz: 120 r/min
    Three-Phase 415 VAC / 50 Hz: 100 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 16.1 N·m
    Three-Phase 380 VAC / 60 Hz: 13.6 N·m
    Three-Phase 400 VAC / 50 Hz: 16.1 N·m
    Three-Phase 400 VAC / 60 Hz: 13.6 N·m
    Three-Phase 415 VAC / 50 Hz: 16.1 N·m
  • Permissible Inertia J: 450×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-15RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
484,33 € * 407,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 150
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 10 r/min
    Three-Phase 380 VAC / 60 Hz: 12 r/min
    Three-Phase 400 VAC / 50 Hz: 10 r/min
    Three-Phase 400 VAC / 60 Hz: 12 r/min
    Three-Phase 415 VAC / 50 Hz: 10 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-150RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 150
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 10 r/min
    Three-Phase 380 VAC / 60 Hz: 12 r/min
    Three-Phase 400 VAC / 50 Hz: 10 r/min
    Three-Phase 400 VAC / 60 Hz: 12 r/min
    Three-Phase 415 VAC / 50 Hz: 10 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-150RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 6 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 150
  • Time Rating: Continuous
  • Rotation Direction: same direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 10 r/min
    Three-Phase 380 VAC / 60 Hz: 12 r/min
    Three-Phase 400 VAC / 50 Hz: 10 r/min
    Three-Phase 400 VAC / 60 Hz: 12 r/min
    Three-Phase 415 VAC / 50 Hz: 10 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
    Three-Phase 380 VAC / 60 Hz: 40 N·m
    Three-Phase 400 VAC / 50 Hz: 40 N·m
    Three-Phase 400 VAC / 60 Hz: 40 N·m
    Three-Phase 415 VAC / 50 Hz: 40 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-150
Versandgewicht:
10,40 kg
Artikelgewicht:
8,00 kg
417,69 € * 351,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 15
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 100 r/min
    Three-Phase 380 VAC / 60 Hz: 120 r/min
    Three-Phase 400 VAC / 50 Hz: 100 r/min
    Three-Phase 400 VAC / 60 Hz: 120 r/min
    Three-Phase 415 VAC / 50 Hz: 100 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 19 N·m
    Three-Phase 380 VAC / 60 Hz: 16 N·m
    Three-Phase 400 VAC / 50 Hz: 19 N·m
    Three-Phase 400 VAC / 60 Hz: 16 N·m
    Three-Phase 415 VAC / 50 Hz: 19 N·m
  • Permissible Inertia J: 450×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 8.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-15
Versandgewicht:
10,60 kg
Artikelgewicht:
8,15 kg
406,98 € * 342,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 120
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 12.5 r/min
    Three-Phase 380 VAC / 60 Hz: 15 r/min
    Three-Phase 400 VAC / 50 Hz: 12.5 r/min
    Three-Phase 400 VAC / 60 Hz: 15 r/min
    Three-Phase 415 VAC / 50 Hz: 12.5 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-120RH
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
514,08 € * 432,00 € exkl. USt.
lieferbar
bei Ihnen eintreffend ca.: ca. 5 Wochen
  • Frame Size: 104 mm
  • Output Power: 200 W
  • Series: BH Series
  • Type: With Terminal Box
  • Gear Ratio: 120
  • Time Rating: Continuous
  • Rotation Direction: opposite direction as the motor shaft
  • Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
    Three-Phase380 VAC / 60 Hz / 0.54 A
    Three-Phase400 VAC / 50 Hz / 0.55 A
    Three-Phase400 VAC / 60 Hz / 0.52 A
    Three-Phase415 VAC / 50 Hz / 0.54 A
  • Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m
  • Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
    Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
    Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min
  • The Speed When Installing Gearhead: Three-Phase 380 VAC / 50 Hz: 12.5 r/min
    Three-Phase 380 VAC / 60 Hz: 15 r/min
    Three-Phase 400 VAC / 50 Hz: 12.5 r/min
    Three-Phase 400 VAC / 60 Hz: 15 r/min
    Three-Phase 415 VAC / 50 Hz: 12.5 r/min
  • Permissible Torque of Gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 60 N·m
    Three-Phase 380 VAC / 60 Hz: 60 N·m
    Three-Phase 400 VAC / 50 Hz: 60 N·m
    Three-Phase 400 VAC / 60 Hz: 60 N·m
    Three-Phase 415 VAC / 50 Hz: 60 N·m
  • Permissible Inertia J: 5000×10⁻⁴ kg·m²
  • Overheat Protective Device Type: Thermal protector
  • Mass: 10.0 kg (With Gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
Artikelnummer:
BHI62UT2-120RA
Versandgewicht:
13,00 kg
Artikelgewicht:
10,00 kg
506,94 € * 426,00 € exkl. USt.