KEMMERICH ELEKTROMOTOREN
Artikelen 1 - 50 van 102
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 320 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 30,0 kW (S1) / 42,0 kW (S6-40%)
- NOMINAAL KOPPEL: 191 Nm (S1) / 267 Nm (S6-40%)
- NOMINALE STROOM: 72,0 A (S1) / 101 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3150 min-1 (S1) / 2250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 332 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1200 min-1
- NOMINALE FREQUENTIE: 41,0 Hz
- UITGANGSVERMOGEN: 25,0 kW (S1) / 35,0 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 58,0 A (S1) / 81,2 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2550 min-1 (S1) / 1800 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 332 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2500 min-1
- NOMINALE FREQUENTIE: 84,5 Hz
- UITGANGSVERMOGEN: 40,0 kW (S1) / 56,0 kW (S6-40%)
- NOMINAAL KOPPEL: 153 Nm (S1) / 214 Nm (S6-40%)
- NOMINALE STROOM: 98,0 A (S1) / 137 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5000 min-1 (S1) / 3500 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 345 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 850 min-1
- NOMINALE FREQUENTIE: 29,5 Hz
- UITGANGSVERMOGEN: 18,5 kW (S1) / 25,9 kW (S6-40%)
- NOMINAAL KOPPEL: 208 Nm (S1) / 291 Nm (S6-40%)
- NOMINALE STROOM: 42,0 A (S1) / 58,8 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1700 min-1 (S1) / 1200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 345 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3000 min-1
- NOMINALE FREQUENTIE: 101,0 Hz
- UITGANGSVERMOGEN: 46,0 kW (S1) / 64,4 kW (S6-40%)
- NOMINAAL KOPPEL: 146 Nm (S1) / 205 Nm (S6-40%)
- NOMINALE STROOM: 106,5 A (S1) / 149 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 850 min-1
- NOMINALE FREQUENTIE: 29,5 Hz
- UITGANGSVERMOGEN: 18,5 kW (S1) / 25,9 kW (S6-40%)
- NOMINAAL KOPPEL: 208 Nm (S1) / 291 Nm (S6-40%)
- NOMINALE STROOM: 38,5 A (S1) / 53,9 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1700 min-1 (S1) / 1200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1200 min-1
- NOMINALE FREQUENTIE: 41,0 Hz
- UITGANGSVERMOGEN: 25,0 kW (S1) / 35,0 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 50,5 A (S1) / 70,7 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2550 min-1 (S1) / 1800 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 30,0 kW (S1) / 42,0 kW (S6-40%)
- NOMINAAL KOPPEL: 191 Nm (S1) / 267 Nm (S6-40%)
- NOMINALE STROOM: 60,5 A (S1) / 84,7 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3150 min-1 (S1) / 2250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2500 min-1
- NOMINALE FREQUENTIE: 84,5 Hz
- UITGANGSVERMOGEN: 40,0 kW (S1) / 56,0 kW (S6-40%)
- NOMINAAL KOPPEL: 153 Nm (S1) / 214 Nm (S6-40%)
- NOMINALE STROOM: 85,4 A (S1) / 120 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5000 min-1 (S1) / 3500 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3000 min-1
- NOMINALE FREQUENTIE: 101,0 Hz
- UITGANGSVERMOGEN: 46,0 kW (S1) / 64,4 kW (S6-40%)
- NOMINAAL KOPPEL: 146 Nm (S1) / 205 Nm (S6-40%)
- NOMINALE STROOM: 96,7 A (S1) / 135 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 900 min-1
- NOMINALE FREQUENTIE: 31,1 Hz
- UITGANGSVERMOGEN: 20,0 kW (S1) / 27,4 kW (S6-40%)
- NOMINAAL KOPPEL: 208 Nm (S1) / 291 Nm (S6-40%)
- NOMINALE STROOM: 38,5 A (S1) / 53,9 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1800 min-1 (S1) / 1250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1260 min-1
- NOMINALE FREQUENTIE: 43,2 Hz
- UITGANGSVERMOGEN: 26,0 kW (S1) / 36,7 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 50,5 A (S1) / 70,7 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2700 min-1 (S1) / 1900 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1580 min-1
- NOMINALE FREQUENTIE: 53,7 Hz
- UITGANGSVERMOGEN: 32,0 kW (S1) / 44,2 kW (S6-40%)
- NOMINAAL KOPPEL: 191 Nm (S1) / 267 Nm (S6-40%)
- NOMINALE STROOM: 60,5 A (S1) / 84,7 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3300 min-1 (S1) / 2350 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2630 min-1
- NOMINALE FREQUENTIE: 88,9 Hz
- UITGANGSVERMOGEN: 42,0 kW (S1) / 58,9 kW (S6-40%)
- NOMINAAL KOPPEL: 153 Nm (S1) / 214 Nm (S6-40%)
- NOMINALE STROOM: 85,4 A (S1) / 120 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5250 min-1 (S1) / 3700 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3160 min-1
- NOMINALE FREQUENTIE: 106,3 Hz
- UITGANGSVERMOGEN: 48,0 kW (S1) / 67,8 kW (S6-40%)
- NOMINAAL KOPPEL: 146 Nm (S1) / 205 Nm (S6-40%)
- NOMINALE STROOM: 96,7 A (S1) / 135 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4400 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 875 min-1
- NOMINALE FREQUENTIE: 30,3 Hz
- UITGANGSVERMOGEN: 19,0 kW (S1) / 26,6 kW (S6-40%)
- NOMINAAL KOPPEL: 207 Nm (S1) / 290 Nm (S6-40%)
- NOMINALE STROOM: 32,7 A (S1) / 45,7 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1750 min-1 (S1) / 1250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1160 min-1
- NOMINALE FREQUENTIE: 39,8 Hz
- UITGANGSVERMOGEN: 24,2 kW (S1) / 33,9 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 40,4 A (S1) / 56,5 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2450 min-1 (S1) / 1750 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1480 min-1
- NOMINALE FREQUENTIE: 50,3 Hz
- UITGANGSVERMOGEN: 30,0 kW (S1) / 42,0 kW (S6-40%)
- NOMINAAL KOPPEL: 194 Nm (S1) / 271 Nm (S6-40%)
- NOMINALE STROOM: 50,0 A (S1) / 70,0 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3150 min-1 (S1) / 2250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2420 min-1
- NOMINALE FREQUENTIE: 81,8 Hz
- UITGANGSVERMOGEN: 38,7 kW (S1) / 54,2 kW (S6-40%)
- NOMINAAL KOPPEL: 153 Nm (S1) / 214 Nm (S6-40%)
- NOMINALE STROOM: 68,3 A (S1) / 95,6 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 4850 min-1 (S1) / 3400 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3180 min-1
- NOMINALE FREQUENTIE: 107,0 Hz
- UITGANGSVERMOGEN: 48,5 kW (S1) / 67,9 kW (S6-40%)
- NOMINAAL KOPPEL: 146 Nm (S1) / 204 Nm (S6-40%)
- NOMINALE STROOM: 84,2 A (S1) / 118 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4500 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 400 / 660 mm
- TRAAGHEIDSMOMENT J: 0,17 kgm2
- ARTIKELGEWICHT: 215,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 315 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2400 min-1
- NOMINALE FREQUENTIE: 81,0 Hz
- UITGANGSVERMOGEN: 50,0 kW (S1) / 70,0 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 124 A (S1) / 174 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5050 min-1 (S1) / 3600 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 325 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1150 min-1
- NOMINALE FREQUENTIE: 39,0 Hz
- UITGANGSVERMOGEN: 30,0 kW (S1) / 42,0 kW (S6-40%)
- NOMINAAL KOPPEL: 249 Nm (S1) / 349 Nm (S6-40%)
- NOMINALE STROOM: 69,5 A (S1) / 97,3 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2450 min-1 (S1) / 1750 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 340 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 780 min-1
- NOMINALE FREQUENTIE: 27,0 Hz
- UITGANGSVERMOGEN: 21,0 kW (S1) / 29,4 kW (S6-40%)
- NOMINAAL KOPPEL: 257 Nm (S1) / 360 Nm (S6-40%)
- NOMINALE STROOM: 47,5 A (S1) / 66,5 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1650 min-1 (S1) / 1200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 342 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3000 min-1
- NOMINALE FREQUENTIE: 101,0 Hz
- UITGANGSVERMOGEN: 56,0 kW (S1) / 78,4 kW (S6-40%)
- NOMINAAL KOPPEL: 178 Nm (S1) / 250 Nm (S6-40%)
- NOMINALE STROOM: 130 A (S1) / 182 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 345 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 37,0 kW (S1) / 51,8 kW (S6-40%)
- NOMINAAL KOPPEL: 236 Nm (S1) / 330 Nm (S6-40%)
- NOMINALE STROOM: 80,5 A (S1) / 113 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3300 min-1 (S1) / 2400 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 780 min-1
- NOMINALE FREQUENTIE: 27,0 Hz
- UITGANGSVERMOGEN: 21,0 kW (S1) / 29,4 kW (S6-40%)
- NOMINAAL KOPPEL: 257 Nm (S1) / 360 Nm (S6-40%)
- NOMINALE STROOM: 42,5 A (S1) / 59,5 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1650 min-1 (S1) / 1200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1150 min-1
- NOMINALE FREQUENTIE: 39,0 Hz
- UITGANGSVERMOGEN: 30,0 kW (S1) / 42,0 kW (S6-40%)
- NOMINAAL KOPPEL: 249 Nm (S1) / 349 Nm (S6-40%)
- NOMINALE STROOM: 59,5 A (S1) / 83,3 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2450 min-1 (S1) / 1750 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 37,0 kW (S1) / 51,8 kW (S6-40%)
- NOMINAAL KOPPEL: 236 Nm (S1) / 330 Nm (S6-40%)
- NOMINALE STROOM: 73,0 A (S1) / 102 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3300 min-1 (S1) / 2400 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2400 min-1
- NOMINALE FREQUENTIE: 81,0 Hz
- UITGANGSVERMOGEN: 50,0 kW (S1) / 70,0 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 103 A (S1) / 144 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5050 min-1 (S1) / 3600 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3000 min-1
- NOMINALE FREQUENTIE: 101,0 Hz
- UITGANGSVERMOGEN: 56,0 kW (S1) / 78,4 kW (S6-40%)
- NOMINAAL KOPPEL: 178 Nm (S1) / 250 Nm (S6-40%)
- NOMINALE STROOM: 117 A (S1) / 164 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 820 min-1
- NOMINALE FREQUENTIE: 28,4 Hz
- UITGANGSVERMOGEN: 22,0 kW (S1) / 30,9 kW (S6-40%)
- NOMINAAL KOPPEL: 257 Nm (S1) / 360 Nm (S6-40%)
- NOMINALE STROOM: 42,5 A (S1) / 59,5 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1750 min-1 (S1) / 1250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1210 min-1
- NOMINALE FREQUENTIE: 41,1 Hz
- UITGANGSVERMOGEN: 32,0 kW (S1) / 44,2 kW (S6-40%)
- NOMINAAL KOPPEL: 249 Nm (S1) / 349 Nm (S6-40%)
- NOMINALE STROOM: 59,5 A (S1) / 83,3 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2600 min-1 (S1) / 1850 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1580 min-1
- NOMINALE FREQUENTIE: 53,7 Hz
- UITGANGSVERMOGEN: 39,0 kW (S1) / 54,5 kW (S6-40%)
- NOMINAAL KOPPEL: 236 Nm (S1) / 330 Nm (S6-40%)
- NOMINALE STROOM: 73,0 A (S1) / 102 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3450 min-1 (S1) / 2550 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2530 min-1
- NOMINALE FREQUENTIE: 85,3 Hz
- UITGANGSVERMOGEN: 53,0 kW (S1) / 73,8 kW (S6-40%)
- NOMINAAL KOPPEL: 199 Nm (S1) / 279 Nm (S6-40%)
- NOMINALE STROOM: 103 A (S1) / 144 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5300 min-1 (S1) / 3800 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3160 min-1
- NOMINALE FREQUENTIE: 106,3 Hz
- UITGANGSVERMOGEN: 59,0 kW (S1) / 82,6 kW (S6-40%)
- NOMINAAL KOPPEL: 178 Nm (S1) / 250 Nm (S6-40%)
- NOMINALE STROOM: 117 A (S1) / 164 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4400 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 790 min-1
- NOMINALE FREQUENTIE: 27,3 Hz
- UITGANGSVERMOGEN: 21,0 kW (S1) / 29,4 kW (S6-40%)
- NOMINAAL KOPPEL: 254 Nm (S1) / 355 Nm (S6-40%)
- NOMINALE STROOM: 35,1 A (S1) / 49,2 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1700 min-1 (S1) / 1200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1210 min-1
- NOMINALE FREQUENTIE: 41,3 Hz
- UITGANGSVERMOGEN: 31,5 kW (S1) / 44,1 kW (S6-40%)
- NOMINAAL KOPPEL: 249 Nm (S1) / 348 Nm (S6-40%)
- NOMINALE STROOM: 51,6 A (S1) / 72,3 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2550 min-1 (S1) / 1850 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1530 min-1
- NOMINALE FREQUENTIE: 52,0 Hz
- UITGANGSVERMOGEN: 37,5 kW (S1) / 52,5 kW (S6-40%)
- NOMINAAL KOPPEL: 234 Nm (S1) / 328 Nm (S6-40%)
- NOMINALE STROOM: 61,1 A (S1) / 85,6 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3400 min-1 (S1) / 2450 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2535 min-1
- NOMINALE FREQUENTIE: 85,5 Hz
- UITGANGSVERMOGEN: 52,5 kW (S1) / 73,5 kW (S6-40%)
- NOMINAAL KOPPEL: 198 Nm (S1) / 277 Nm (S6-40%)
- NOMINALE STROOM: 89,3 A (S1) / 125 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5350 min-1 (S1) / 3850 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3030 min-1
- NOMINALE FREQUENTIE: 102,0 Hz
- UITGANGSVERMOGEN: 56,5 kW (S1) / 79,1 kW (S6-40%)
- NOMINAAL KOPPEL: 178 Nm (S1) / 249 Nm (S6-40%)
- NOMINALE STROOM: 97,5 A (S1) / 137 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 450 / 710 mm
- TRAAGHEIDSMOMENT J: 0,21 kgm2
- ARTIKELGEWICHT: 242,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 332 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 800 min-1
- NOMINALE FREQUENTIE: 27,5 Hz
- UITGANGSVERMOGEN: 26,0 kW (S1) / 36,4 kW (S6-40%)
- NOMINAAL KOPPEL: 310 Nm (S1) / 435 Nm (S6-40%)
- NOMINALE STROOM: 61,0 A (S1) / 85,4 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1800 min-1 (S1) / 1300 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 332 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3100 min-1
- NOMINALE FREQUENTIE: 104,0 Hz
- UITGANGSVERMOGEN: 70,0 kW (S1) / 98,0 kW (S6-40%)
- NOMINAAL KOPPEL: 216 Nm (S1) / 302 Nm (S6-40%)
- NOMINALE STROOM: 168 A (S1) / 235 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4650 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 340 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 45,0 kW (S1) / 63,0 kW (S6-40%)
- NOMINAAL KOPPEL: 287 Nm (S1) / 401 Nm (S6-40%)
- NOMINALE STROOM: 99,3 A (S1) / 139 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3600 min-1 (S1) / 2700 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 340 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2400 min-1
- NOMINALE FREQUENTIE: 80,7 Hz
- UITGANGSVERMOGEN: 60,0 kW (S1) / 84,0 kW (S6-40%)
- NOMINAAL KOPPEL: 239 Nm (S1) / 334 Nm (S6-40%)
- NOMINALE STROOM: 139 A (S1) / 195 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 3850 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 345 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1200 min-1
- NOMINALE FREQUENTIE: 41,0 Hz
- UITGANGSVERMOGEN: 37,0 kW (S1) / 51,8 kW (S6-40%)
- NOMINAAL KOPPEL: 294 Nm (S1) / 412 Nm (S6-40%)
- NOMINALE STROOM: 81,0 A (S1) / 113 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2650 min-1 (S1) / 1950 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 800 min-1
- NOMINALE FREQUENTIE: 27,5 Hz
- UITGANGSVERMOGEN: 26,0 kW (S1) / 36,4 kW (S6-40%)
- NOMINAAL KOPPEL: 310 Nm (S1) / 435 Nm (S6-40%)
- NOMINALE STROOM: 53,0 A (S1) / 74,2 A (S6-40%)
- RENDEMENT: 89,0 %
- KONSTANTvermogenSBEREICH max.: 1800 min-1 (S1) / 1300 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1200 min-1
- NOMINALE FREQUENTIE: 41,0 Hz
- UITGANGSVERMOGEN: 37,0 kW (S1) / 51,8 kW (S6-40%)
- NOMINAAL KOPPEL: 294 Nm (S1) / 412 Nm (S6-40%)
- NOMINALE STROOM: 73,5 A (S1) / 103 A (S6-40%)
- RENDEMENT: 92,0 %
- KONSTANTvermogenSBEREICH max.: 2650 min-1 (S1) / 1950 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1500 min-1
- NOMINALE FREQUENTIE: 51,0 Hz
- UITGANGSVERMOGEN: 45,0 kW (S1) / 63,0 kW (S6-40%)
- NOMINAAL KOPPEL: 287 Nm (S1) / 401 Nm (S6-40%)
- NOMINALE STROOM: 89,0 A (S1) / 125 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3600 min-1 (S1) / 2700 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2400 min-1
- NOMINALE FREQUENTIE: 80,7 Hz
- UITGANGSVERMOGEN: 60,0 kW (S1) / 84,0 kW (S6-40%)
- NOMINAAL KOPPEL: 239 Nm (S1) / 334 Nm (S6-40%)
- NOMINALE STROOM: 125 A (S1) / 175 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 3850 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 380 V
- AANTAL POLEN: 4
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 3100 min-1
- NOMINALE FREQUENTIE: 104,0 Hz
- UITGANGSVERMOGEN: 70,0 kW (S1) / 98,0 kW (S6-40%)
- NOMINAAL KOPPEL: 216 Nm (S1) / 302 Nm (S6-40%)
- NOMINALE STROOM: 147 A (S1) / 206 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 5500 min-1 (S1) / 4650 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (4000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O: 510 / 770 mm
- TRAAGHEIDSMOMENT J: 0,25 kgm2
- ARTIKELGEWICHT: 275,00 kg
Artikelen 1 - 50 van 102