KEMMERICH ELEKTROMOTOREN
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 530 min-1
- NOMINALE FREQUENTIE: 26,8 Hz
- UITGANGSVERMOGEN: 100 kW (S1) / 130 kW (S6-40%)
- NOMINAAL KOPPEL: 1800 Nm (S1) / 2340 Nm (S6-40%)
- NOMINALE STROOM: 185 A (S1) / 245 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 1050 min-1 (S1) / 800 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 670 / 1090 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 8,0 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1000 min-1
- NOMINALE FREQUENTIE: 50,3 Hz
- UITGANGSVERMOGEN: 180 kW (S1) / 235 kW (S6-40%)
- NOMINAAL KOPPEL: 1720 Nm (S1) / 2240 Nm (S6-40%)
- NOMINALE STROOM: 325 A (S1) / 430 A (S6-40%)
- RENDEMENT: 94,5 %
- KONSTANTvermogenSBEREICH max.: 2050 min-1 (S1) / 1600 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 670 / 1090 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 8,0 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1450 min-1
- NOMINALE FREQUENTIE: 72,8 Hz
- UITGANGSVERMOGEN: 245 kW (S1) / 320 kW (S6-40%)
- NOMINAAL KOPPEL: 1610 Nm (S1) / 2110 Nm (S6-40%)
- NOMINALE STROOM: 435 A (S1) / 570 A (S6-40%)
- RENDEMENT: 95,0 %
- KONSTANTvermogenSBEREICH max.: 3000 min-1 (S1) / 2350 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 670 / 1090 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 8,0 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2000 min-1
- NOMINALE FREQUENTIE: 100,3 Hz
- UITGANGSVERMOGEN: 310 kW (S1) / 405 kW (S6-40%)
- NOMINAAL KOPPEL: 1480 Nm (S1) / 1930 Nm (S6-40%)
- NOMINALE STROOM: 555 A (S1) / 715 A (S6-40%)
- RENDEMENT: 95,5 %
- KONSTANTvermogenSBEREICH max.: 3200 min-1 (S1) / 3200 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 670 / 1090 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 8,0 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 530 min-1
- NOMINALE FREQUENTIE: 26,8 Hz
- UITGANGSVERMOGEN: 130 kW (S1) / 170 kW (S6-40%)
- NOMINAAL KOPPEL: 2350 Nm (S1) / 3060 Nm (S6-40%)
- NOMINALE STROOM: 240 A (S1) / 310 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 1100 min-1 (S1) / 850 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 780 / 1200 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 10 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 980 min-1
- NOMINALE FREQUENTIE: 49,3 Hz
- UITGANGSVERMOGEN: 230 kW (S1) / 300 kW (S6-40%)
- NOMINAAL KOPPEL: 2240 Nm (S1) / 2920 Nm (S6-40%)
- NOMINALE STROOM: 415 A (S1) / 540 A (S6-40%)
- RENDEMENT: 95,0 %
- KONSTANTvermogenSBEREICH max.: 2150 min-1 (S1) / 1650 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 780 / 1200 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 10 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1470 min-1
- NOMINALE FREQUENTIE: 73,8 Hz
- UITGANGSVERMOGEN: 325 kW (S1) / 420 kW (S6-40%)
- NOMINAAL KOPPEL: 2110 Nm (S1) / 2730 Nm (S6-40%)
- NOMINALE STROOM: 580 A (S1) / 750 A (S6-40%)
- RENDEMENT: 95,5 %
- KONSTANTvermogenSBEREICH max.: 3100 min-1 (S1) / 2400 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 780 / 1200 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 10 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2020 min-1
- NOMINALE FREQUENTIE: 101,3 Hz
- UITGANGSVERMOGEN: 410 kW (S1) / 530 kW (S6-40%)
- NOMINAAL KOPPEL: 1940 Nm (S1) / 2510 Nm (S6-40%)
- NOMINALE STROOM: 740 A (S1) / 950 A (S6-40%)
- RENDEMENT: 95,5 %
- KONSTANTvermogenSBEREICH max.: 3200 min-1 (S1) / 3200 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 780 / 1200 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 10 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 540 min-1
- NOMINALE FREQUENTIE: 27,3 Hz
- UITGANGSVERMOGEN: 170 kW (S1) / 220 kW (S6-40%)
- NOMINAAL KOPPEL: 3010 Nm (S1) / 3890 Nm (S6-40%)
- NOMINALE STROOM: 305 A (S1) / 400 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 1150 min-1 (S1) / 900 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 900 / 1320 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 13 kgm2
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 970 min-1
- NOMINALE FREQUENTIE: 48,8 Hz
- UITGANGSVERMOGEN: 290 kW (S1) / 375 kW (S6-40%)
- NOMINAAL KOPPEL: 2860 Nm (S1) / 3690 Nm (S6-40%)
- NOMINALE STROOM: 520 A (S1) / 670 A (S6-40%)
- RENDEMENT: 95,0 %
- KONSTANTvermogenSBEREICH max.: 2150 min-1 (S1) / 1650 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 19,6/11,3A 5,5kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (2400 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- AFMETINGEN B/O/X/Y/Z: 900 / 1320 / 585 / 395 / 585 mm
- TRAAGHEIDSMOMENT J: 13 kgm2