KEMMERICH ELEKTROMOTOREN
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1100 min-1
- NOMINALE FREQUENTIE: 55,4 Hz
- UITGANGSVERMOGEN: 196 kW (S1) / 275 kW (S6-40%)
- NOMINAAL KOPPEL: 1710 Nm (S1) / 2390 Nm (S6-40%)
- NOMINALE STROOM: 380 A (S1) / 535 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 3150 min-1 (S1) / 1800 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1320 min-1
- NOMINALE FREQUENTIE: 66,4 Hz
- UITGANGSVERMOGEN: 232 kW (S1) / 325 kW (S6-40%)
- NOMINAAL KOPPEL: 1680 Nm (S1) / 2360 Nm (S6-40%)
- NOMINALE STROOM: 445 A (S1) / 625 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2150 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1650 min-1
- NOMINALE FREQUENTIE: 82,9 Hz
- UITGANGSVERMOGEN: 283 kW (S1) / 400 kW (S6-40%)
- NOMINAAL KOPPEL: 1640 Nm (S1) / 2320 Nm (S6-40%)
- NOMINALE STROOM: 545 A (S1) / 765 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2650 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1960 min-1
- NOMINALE FREQUENTIE: 98,4 Hz
- UITGANGSVERMOGEN: 321 kW (S1) / 455 kW (S6-40%)
- NOMINAAL KOPPEL: 1570 Nm (S1) / 2220 Nm (S6-40%)
- NOMINALE STROOM: 615 A (S1) / 865 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3150 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 850 min-1
- NOMINALE FREQUENTIE: 42,9 Hz
- UITGANGSVERMOGEN: 156 kW (S1) / 220 kW (S6-40%)
- NOMINAAL KOPPEL: 1760 Nm (S1) / 2475 Nm (S6-40%)
- NOMINALE STROOM: 265 A (S1) / 375 A (S6-40%)
- RENDEMENT: 91,5 %
- KONSTANTvermogenSBEREICH max.: 2450 min-1 (S1) / 1400 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1270 min-1
- NOMINALE FREQUENTIE: 63,9 Hz
- UITGANGSVERMOGEN: 226 kW (S1) / 320 kW (S6-40%)
- NOMINAAL KOPPEL: 1700 Nm (S1) / 2410 Nm (S6-40%)
- NOMINALE STROOM: 380 A (S1) / 535 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2050 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1520 min-1
- NOMINALE FREQUENTIE: 76,4 Hz
- UITGANGSVERMOGEN: 267 kW (S1) / 375 kW (S6-40%)
- NOMINAAL KOPPEL: 1680 Nm (S1) / 2360 Nm (S6-40%)
- NOMINALE STROOM: 445 A (S1) / 625 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2450 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1900 min-1
- NOMINALE FREQUENTIE: 95,4 Hz
- UITGANGSVERMOGEN: 325 kW (S1) / 460 kW (S6-40%)
- NOMINAAL KOPPEL: 1640 Nm (S1) / 2315 Nm (S6-40%)
- NOMINALE STROOM: 545 A (S1) / 765 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3050 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2260 min-1
- NOMINALE FREQUENTIE: 113,4 Hz
- UITGANGSVERMOGEN: 370 kW (S1) / 520 kW (S6-40%)
- NOMINAAL KOPPEL: 1565 Nm (S1) / 2200 Nm (S6-40%)
- NOMINALE STROOM: 615 A (S1) / 865 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3500 min-1 (S6-40%)
- KOELING: IC416R (met filter op aanvraag), standaard ventilator 3x230/400 Vac 50 Hz 11,2/6,4A 3,0kW
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 780 min-1
- NOMINALE FREQUENTIE: 39,4 Hz
- UITGANGSVERMOGEN: 128 kW (S1) / 180 kW (S6-40%)
- NOMINAAL KOPPEL: 1570 Nm (S1) / 2210 Nm (S6-40%)
- NOMINALE STROOM: 250 A (S1) / 350 A (S6-40%)
- RENDEMENT: 91,5 %
- KONSTANTvermogenSBEREICH max.: 2250 min-1 (S1) / 1250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1160 min-1
- NOMINALE FREQUENTIE: 58,4 Hz
- UITGANGSVERMOGEN: 185 kW (S1) / 260 kW (S6-40%)
- NOMINAAL KOPPEL: 1525 Nm (S1) / 2145 Nm (S6-40%)
- NOMINALE STROOM: 355 A (S1) / 500 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3350 min-1 (S1) / 1900 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1390 min-1
- NOMINALE FREQUENTIE: 69,9 Hz
- UITGANGSVERMOGEN: 218 kW (S1) / 310 kW (S6-40%)
- NOMINAAL KOPPEL: 1500 Nm (S1) / 2140 Nm (S6-40%)
- NOMINALE STROOM: 415 A (S1) / 585 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2250 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1730 min-1
- NOMINALE FREQUENTIE: 86,9 Hz
- UITGANGSVERMOGEN: 266 kW (S1) / 375 kW (S6-40%)
- NOMINAAL KOPPEL: 1470 Nm (S1) / 2075 Nm (S6-40%)
- NOMINALE STROOM: 510 A (S1) / 715 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2800 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 400 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2060 min-1
- NOMINALE FREQUENTIE: 103,4 Hz
- UITGANGSVERMOGEN: 302 kW (S1) / 425 kW (S6-40%)
- NOMINAAL KOPPEL: 1405 Nm (S1) / 1975 Nm (S6-40%)
- NOMINALE STROOM: 575 A (S1) / 805 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3300 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 900 min-1
- NOMINALE FREQUENTIE: 45,4 Hz
- UITGANGSVERMOGEN: 147 kW (S1) / 210 kW (S6-40%)
- NOMINAAL KOPPEL: 1565 Nm (S1) / 2230 Nm (S6-40%)
- NOMINALE STROOM: 250 A (S1) / 350 A (S6-40%)
- RENDEMENT: 91,5 %
- KONSTANTvermogenSBEREICH max.: 2600 min-1 (S1) / 1450 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1340 min-1
- NOMINALE FREQUENTIE: 67,4 Hz
- UITGANGSVERMOGEN: 212 kW (S1) / 300 kW (S6-40%)
- NOMINAAL KOPPEL: 1515 Nm (S1) / 2140 Nm (S6-40%)
- NOMINALE STROOM: 355 A (S1) / 500 A (S6-40%)
- RENDEMENT: 92,5 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2150 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 1600 min-1
- NOMINALE FREQUENTIE: 80,4 Hz
- UITGANGSVERMOGEN: 251 kW (S1) / 355 kW (S6-40%)
- NOMINAAL KOPPEL: 1500 Nm (S1) / 2120 Nm (S6-40%)
- NOMINALE STROOM: 415 A (S1) / 585 A (S6-40%)
- RENDEMENT: 93,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 2600 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2000 min-1
- NOMINALE FREQUENTIE: 100,4 Hz
- UITGANGSVERMOGEN: 306 kW (S1) / 430 kW (S6-40%)
- NOMINAAL KOPPEL: 1465 Nm (S1) / 2055 Nm (S6-40%)
- NOMINALE STROOM: 510 A (S1) / 715 A (S6-40%)
- RENDEMENT: 93,5 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3200 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg
- BESCHERMINGSGRAAD: IP54
- NOMINALE SPANNING: 460 V
- AANTAL POLEN: 6
- BEDRIJFSMODUS: S1 / S6-40%
- NOMINAAL TOERENTAL: 2380 min-1
- NOMINALE FREQUENTIE: 119,4 Hz
- UITGANGSVERMOGEN: 347 kW (S1) / 490 kW (S6-40%)
- NOMINAAL KOPPEL: 1395 Nm (S1) / 1970 Nm (S6-40%)
- NOMINALE STROOM: 575 A (S1) / 805 A (S6-40%)
- RENDEMENT: 94,0 %
- KONSTANTvermogenSBEREICH max.: 3500 min-1 (S1) / 3500 min-1 (S6-40%)
- KOELING: IC416A, standaard ventilator 3x400 Vac 50/60 Hz 0,48/0,53A 340/400W
- ISOLATIEKLASSE: F
- OMGEVINGSCONDITIES: 0 tot +40 °C, 1000 m BOVEN ZEENIVEAU
- MAX. MECHANISCH TOERENTAL: (3000 min-1 rollager; mogelijk verder beperkt door encoderterugkoppeling of rem
- TRAAGHEIDSMOMENT J: 4,8 kgm2
- ARTIKELGEWICHT: 1492,00 kg